Pushing a Frozen CXR Foundation Model: A LoRA Partial-Fine-Tuning Study on NIH ChestX-ray14 with a Model-Conditional Label-Flip Sensitivity Analysis
T.-C. BAI, S.-C. YEH
Key points
From the paper's conclusion- We report a retrospective study of Low-Rank Adaptation (LoRA) of Rad-DINO Vision Transformer Base with 14x14 patches (ViT-B/14) for 14-class multi-label classification on the National Institutes of Health (NIH) ChestX-ray14 dataset.
Abstract
Foundation models for chest X-ray interpretation make it possible to adapt specialised visual representations with relatively small trainable modules. We report a retrospective study of Low-Rank Adaptation (LoRA) of Rad-DINO Vision Transformer Base with 14x14 patches (ViT-B/14) for 14-class multi-label classification on the National Institutes of Health (NIH) ChestX-ray14 dataset. The official test labels were accessed during earlier model development and configuration comparisons; consequently, every official-test result in this manuscript is explicitly descriptive and non-confirmatory. We used a patient-disjoint 90/10 split of the official trainval pool (77,988 training and 8,536 validation images) and retained the released 25,596-image test partition. The historically selected all-linear LoRA configuration with safe augmentation and g=37 produced a descriptive test macro AUROC of 0.8462 versus the frozen baseline of 0.8295. Comparisons of target modules, patch-token grids, and a Rad-DINO-specific local query head are reported as retrospective comparisons rather than unbiased model-selection evidence. A confident-learning diagnostic flagged 17,653 of 86,524 trainval images (20.4%); this is a model-based flag rate, not a ground-truth label-error rate. A separate counterfactual relabeling sensitivity analysis, which uses the same model to identify and rescore disagreements, changed the descriptive AUROC to approximately 0.9445 after 6,509 policy-defined flips. This value is not achieved model performance and is not a radiologist-audited label-quality ceiling. We provide a validation-only threshold and artifact protocol for future locked evaluation, but a genuinely untouched holdout and new locked selection are required for a confirmatory headline. The existing Zenodo record contains the 25 publication figures only.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- RoentMod: a synthetic chest X-ray modification model to identify and correct image interpretation model shortcutsnpj Digital Medicine · 2026
- Advancing human-centric AI for robust X-ray analysis through holistic self-supervised learning.Nature communications · 2026
- Pre-training, Reasoning, Benchmarking: X-ray Report Generation on CheXpert Plus DatasetarXiv · 2026
- Is a CNN-Transformer Ensemble Worth It When a Chest X-Ray Foundation Model Is Available?arXiv · 2026
- Med-AR: Autoregressive Vision-Language Pretraining for Long-Tailed Chest X-Ray Classification and Uncertainty-Aware EvaluationarXiv · 2026
- Out-of-Distribution Generalization of Pretrained Multi-Label Chest X-Ray Classifiers: A Retrospective External Validation of Seven Models.Diagnostics (Basel, Switzerland) · 2026