DB-ATRG: The Density and BI-RADS-Aware Triage and Automatic Report Generation System for Mammography
V. Phan, N. N. C. Tran, N. T. D. Bui, R. Jeter
Key points
From the paper's conclusion- Objective: This study introduces the Density and BI-RADS--Aware Triage and Report Generation (DB-ATRG) framework to fundamentally restructure mammography workflows by automating diagnostic text generation and enabling risk-based case prioritization.
Abstract
BackgroundThe growing volume of mammography screenings has created severe radiologist shortages, while standard First-In, First-Out (FIFO) reading queues fail to prioritize urgent or complex cases, delaying critiScal diagnoses.
ObjectiveThis study introduces the Density and BI-RADS-Aware Triage and Report Generation (DB-ATRG) framework to fundamentally restructure mammography workflows by automating diagnostic text generation and enabling risk-based case prioritization.
MethodsUtilizing the Digital Mammography Dataset for Breast Cancer Diagnosis Research (DMID), we fine-tuned the 4-billion parameter MedGemma 1.5 vision-language model using Quantization and Low-Rank Adaptation (QLoRA). The extracted biomarkers drive a dual-phase triage algorithm that flags extremely dense breasts (ACR Category D) for supplemental screening and dynamically ranks remaining cases using a calculated Cumulative Urgency Score. The clinical impact of this triage workflow was evaluated against a standard FIFO queue using a simulated cohort of 100 mammography cases.
ResultsDB-ATRG achieved significant improvements over the AMRG baseline in clinical text generation and classification, securing a ROUGE-L score of 0.8012, a METEOR score of 0.8358, and an ACR Density Accuracy of 0.6810. In clinical simulations, the optimized prioritization queue captured 100.0% of high-risk malignancies (BI-RADS 4 and 5) within the first 20% of the reading workload, compared to just 19.2% in the random FIFO queue. This framework effectively accelerated the mean rank position of severe cases from 42.0 down to 7.5.
ConclusionBy accurately automating report generation and aggressively prioritizing severe cases, the DB-ATRG framework can drastically optimize clinical resource allocation and accelerate the time-to-diagnosis for the most vulnerable patients.
HighlightsO_LIA vision-language model (MedGemma 1.5 4B) is fine-tuned with QLoRA for automated mammography report generation, achieving ROUGE-L 0.8012 and METEOR 0.8358. C_LIO_LIA dual-phase Density and BI-RADS-Aware Triage algorithm restructures FIFO reading queues by clinical urgency. C_LIO_LIThe triage system captures 100.0% of high-risk cases (BI-RADS 4/5) within the first 20% of the worklist, versus 19.2% in standard FIFO. C_LIO_LIACR breast density classification accuracy reaches 0.6810, enabling reliable density-based complexity filtering. C_LI
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- AI as a Safety Net Reader for Mammograms Classified as Normal or Benign in the French Screening ProgramRadiology Artificial Intelligence · 2026
- Two-stage synthetic-to-real transfer learning for automated mammography report generation using vision-language modelsScientific Reports · 2026
- Reading the Mask: Descriptor-Grounded BI-RADS Rationale Generation for Breast MRI SegmentationarXiv · 2026
- From Density to Biopsy Decisions and Malignancy Prediction: A Benchmark Study of Multimodal Large Language Models Against Radiologists in Digital and Contrast-Enhanced MammographyarXiv · 2026
- Measuring Radiologist Workload After AI Triage in Breast Cancer Screening.Academic radiology · 2026
- CliQ-RRG: Clinical-Knowledge Guided Disease-aware Visual-Textual Alignment for QA-Style Radiology Report GenerationarXiv · 2026