Two-stage synthetic-to-real transfer learning for automated mammography report generation using vision-language models
Gani Esen, Marat Nurtas, Jandos Amankulov, Laura La Paglia
Key points
From the paper's conclusion- We present a two-stage synthetic-to-real training pipeline for automated mammography report generation, together with a controlled, preregistered evaluation of whether its synthetic pretraining stage contributes to final report quality.
Abstract
We present a two-stage synthetic-to-real training pipeline for automated mammography report generation, together with a controlled, preregistered evaluation of whether its synthetic pretraining stage contributes to final report quality. Automated mammography report generation is constrained by the scarcity of paired mammogram-report data: public collections such as VinDr-Mammo and CBIS-DDSM provide structured annotations but no free-text reports. The pipeline converts BI-RADS annotations into synthetic reports (400 generated, 390 retained) to pretrain MedGemma-4B with multimodal LoRA, then fine-tunes on 407 real DMID reports. On the leak-free DMID test subset ( $$n = 49$$ ) it reaches ROUGE-L 0.656, METEOR 0.666, CIDEr 0.649 and BERTScore 0.917, exceeding every external baseline, including the published state of the art. The evaluation then shows that synthetic pretraining does not produce these numbers: the apparent advantage was measured between models of unequal adapter capacity, and at matched capacity the two schemes are equivalent. Across 60 training runs over three corpus sizes, three capacities and five initialisations, against a margin fixed in advance, no configuration favours two-stage training; capacity alone reproduces the gap. Two findings bear on evaluation. Under an assertion-level criterion no model fabricates findings on normal studies; the failure mode is omission. Textual and clinical quality diverge within one model: where two-stage training gains 0.058 ROUGE-L, BI-RADS agreement and sensitivity both fall. With agreement never exceeding $$\kappa = 0.14$$ , the obstacle to clinically useful reporting is diagnostic accuracy, not fluency.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Scaling medical imaging report generation with multimodal reinforcement learningNature Communications · 2026
- RadMultiBench: A Reproducible Dual-Task Benchmark Exposing the Limits of Pre-Trained Vision-Language Models Across Thoracic and Breast ImagingbioRxiv · 2026
- XGeM: A multi-prompt foundation model for multimodal medical data generationComputerized Medical Imaging and Graphics · 2026
- Enhanced vision language framework for medical report generation using agent-based retrieval.Frontiers in digital health · 2026
- CliQ-RRG: Clinical-Knowledge Guided Disease-aware Visual-Textual Alignment for QA-Style Radiology Report GenerationarXiv · 2026
- Benchmarking Open-Source Large Language Models for Breast Ultrasound Report Processing: A Multicenter Study.Diagnostics (Basel, Switzerland) · 2026