Real-time AI integration for MR to detect artifacts and guide pulse sequence adaptations
A. T. Gudmundson, Z. Shams, A. Gad, S. Wang, D. Simicic, S. Murali-Manohar, G. L. Simegn, I. Özdemir,
Key points
From the paper's conclusion- PEREGRINE enabled an adaptive and AI-integrated sequence allowing for real-time evaluation and response to OOV artifacts, identifying gradient modifications that produced less OOV contamination.
Abstract
This work presents a first-of-its-kind artificial intelligence (AI-)integrated MR pulse sequence that detects out-of-voxel (OOV) artifacts in real-time (within-TR) and responds prospectively by updating the crusher gradient scheme. Per Excitation Real-time Execution & Guided Responses with Integrated Neural-network Evaluation (PEREGRINE), allows for deployment of deep learning models and pulse sequence updates. In this study, PEREGRINE operated a time-domain (TD) and frequency-domain (FD) convolutional autoencoder that detect OOV artifacts. Scans without (AI-off) and with (AI-on) updates were collected from the medial prefrontal cortex of healthy volunteers using a MEGA-edited MRS experiment. The degree of OOV contamination (OOV Score) was quantified per transient based upon the prevalence of OOV signals in the TD and FD data. OOV Scores above a user-defined threshold triggered an update of the crusher gradient scheme, iterating through 48 permutations (6 axis transpositions x 8 polarity flips). Within each 2-second TR, PEREGRINE successfully provided single-transient OOV Scores and updated gradients accordingly. No difference was observed between the OOV Scores from the full ('Full' condition) AI-on and AI-off sessions due to the AI-on scan cycling over better and worse gradient permutations relative to the AI-off scan. However, the AI-on scan had significantly lower OOV Scores than the AI-off scan when selecting the transients where PEREGRINE persisted ('Dwell' condition) on a given gradient permutation. Ultimately, Fit Quality Number (FQN) from linear combination modeling improved significantly for the AI-on compared to the AI-off scan. PEREGRINE enabled an adaptive and AI-integrated sequence allowing for real-time evaluation and response to OOV artifacts, identifying gradient modifications that produced less OOV contamination.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A closed-loop agentic research environment for MRI development within Siemens IDEA platformarXiv · 2026
- The Current Status of AI-accelerated MRI Techniques in Clinical UseRadiology · 2025
- SmartBloch-Agent: An Agentic Framework for Automated MRI Sequence Design and OptimizationarXiv · 2026
- Measure Before You Repair: An Explainable Agent for Blind Restoration of Multi-Artifact 3-D MRIarXiv · 2026
- A Deep Learning Framework for Retrospective Motion Detection and Conditional Correction (MDCC): Application to Multi-Gradient-Recalled Echo Quantitative MRI.Journal of imaging informatics in medicine · 2026
- Robust T1ρ , T2 , and T2 * mapping via spin-locked MOLED with synthetic data-driven deep learning reconstruction.Physics in medicine and biology · 2026