Journal of imaging informatics in medicine

A Deep Learning Framework for Retrospective Motion Detection and Conditional Correction (MDCC): Application to Multi-Gradient-Recalled Echo Quantitative MRI.

Gulfam Ahmed Saju, Jeramy Lewis, Satya V V N Kothapalli, Cihat Eldeniz, Dmitriy A Yablonskiy

Mallinckrodt Institute of Radiology, Washington University School of Medicine in St. Louis, 4525 Scott Avenue, St. Louis, MO, 63110, USA. gsaju@wustl.edu. · Mallinckrodt Institute of Radiology, Washington University School of Medicine in St. Louis, 4525 Scott Avenue, St. Louis, MO, 63110, USA.

Observational

Key points

From the paper's conclusion
  • We propose Motion Detection and Conditional Correction (MDCC), a retrospective image-domain pipeline that couples a complex-input volume-level Multi-Echo Motion Detection (ME-MoD) model and a complex-valued Multi-Echo Motion Corrector (ME-MoC) in an iterative detect–correct–re-evaluate loop, where correction is invoked only on volumes flagged as motion corrupted.

Abstract

Multi-echo gradient-recalled-echo (mGRE) MRI supports quantitative neuroimaging by enabling voxel-wise T2*/R2*/R2t* mapping for quantitative assessment of tissue damage and magnetic susceptibility imaging. Subject motion degrades these acquisitions by introducing inconsistencies due to phase-encoding steps collected at different head positions. Although the gradient echoes associated with a given phase-encoding line are acquired at practically the same head position, differences in contrast, signal-to-noise ratio, and B0 field-dependent phase evolution cause the resulting artifacts to appear differently across echoes and can bias downstream parametric maps. Existing learning-based retrospective correction approaches often discard complex phase information, treat multiple gradient-recalled echoes independently, and apply correction indiscriminately to both motion-corrupted and clean data. We propose Motion Detection and Conditional Correction (MDCC), a retrospective image-domain pipeline that couples a complex-input volume-level Multi-Echo Motion Detection (ME-MoD) model and a complex-valued Multi-Echo Motion Corrector (ME-MoC) in an iterative detect-correct-re-evaluate loop, where correction is invoked only on volumes flagged as motion corrupted. ME-MoD reweights each echo with a phase-preserving paired complex gate, followed by a shared residual slice encoder, and a selected volume-level aggregator. ME-MoC is a fully complex-valued, factorized U-Net with echo-axis multi-head self-attention at the bottleneck, trained with a T2*-consistency physics loss. ME-MoD attained an AUC of 0.95 and sensitivity of 0.91 on the held-out detection set. At the cohort-level analysis, ME-MoC improved downstream R2* fitting results relative to the motion-corrupted input and 2D U-Net and achieved the lowest numerical R2* root-mean-square error (RMSE) among the evaluated methods, including modest numerical improvement over baseline.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A Deep Learning Framework for Retrospective Motion Detection and Conditional Correction (MDCC): Application to Multi-Gradient-Recalled Echo Quantitative MRI — Science Skim