Assessment of Minidock MTB for the diagnosis of tuberculosis from sputum in patients presenting to health facilities in Indonesia
S. Hartati, R. C. Koesoemadinata, K. J. Sharples, S. M. McAllister, L. Chaidir, I. Setiaputri, E. Emmanuel, R. van Crevel,
Key points
From the paper's conclusion- Overall agreement between MiniDock MTB and Xpert (excluding trace positive) was 94.8% (95% CI 92.6 - 96.3; K = 0.84).
Abstract
BackgroundAccess to tuberculosis (TB) diagnostics remains limited in high-burden countries, partly due to centralised and complex testing. We evaluated MiniDock MTB, a low-complexity near point-of-care (nPOC) assay, in sputum for diagnostic accuracy and agreement with Xpert MTB/RIF Ultra (Xpert).
MethodsFrom September 2024 to April 2025, presumptive pulmonary TB cases aged >28 days were consecutively enrolled at 15 community health centres, a lung clinic, and a lung hospital in Bandung, Indonesia. Sputum was tested with MiniDock MTB on sputum swab, Xpert, and liquid culture. We assessed diagnostic accuracy against microbiological and composite reference standards (CRS) and agreement with Xpert.
ResultsFrom 3051 individuals screened, 671 were eligible and included; 533 were adults (aged [≥]15 years), 138 were children. Overall, 126 were Xpert-positive and 132 culture-positive. In adults, MiniDock MTB sensitivity was 86.2% (100/116; 95% CI 78.8 - 91.3) and 55.8% (110/197; 95% CI 48.9 - 62.6) against liquid culture and CRS, respectively; small numbers of positive results precluded estimation in children. Specificity ranged from 96.8% to 98.8%. Overall agreement between MiniDock MTB and Xpert (excluding trace positive) was 94.8% (95% CI 92.6 - 96.3; K = 0.84). Positive percent agreement was 82.8% (95% CI 75.1 - 88.4) and 25% (95% CI 4.6 - 69.9) in adults and children, respectively, and reduced with lower bacillary burden (p = 0.004).
ConclusionsSensitivity of MiniDock MTB in sputum against liquid culture exceeded the WHO threshold for a sputum-based nPOC TB test in adults. There was high agreement with Xpert but reduced sensitivity in low-bacillary burden TB disease.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Pulmonary Tuberculosis Detection with MiniDock MTB Using Swab SamplesNew England Journal of Medicine · 2026
- Association of Pluslife MiniDock MTB time-to-positivity with tuberculosis bacterial load: a diagnostic study in IndonesiamedRxiv · 2026
- Diagnostic accuracy of a novel point-of-care tongue swab assay for pulmonary tuberculosis: a multicentre prospective studyClinical Microbiology and Infection · 2025
- Diagnostic Performance of the Pluslife MiniDock MTB and Molbio MTB Ultima Assays to Detect Tuberculosis From Tongue and Sputum Swabs Among Outpatients and in Active Case Finding in CameroonClinical Infectious Diseases · 2025
- Diagnostic accuracy of swab-based molecular tests for tuberculosis using near-point-of-care platforms: a multi-country evaluationEBioMedicine · 2025
- Diagnostic accuracy and testing efficiency of pooled testing of sputum swabs to detect tuberculosis on the near point of care Pluslife MiniDock MTB assaymedRxiv · 2026