科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ International Journal of AI Electrical Civil and Mechanical engineering2026-07-31· Reinforced concrete

RISK ASSESSMENT OF AN ETABS-BASED MULTI-STOREY RESIDENTIAL REINFORCED CONCRETE STRUCTURE

BOLLAM GANESH, Mr. V. SRINIVASA RAO, Dr. B. SHARATH CHANDRA

原始摘要(英文原文)· Original abstract
During their useful lives, structures endure a variety of loadings, such as those caused by gravity, seismic forces, and wind activities. Academic research on buildings using reinforced concrete (RC) frames often focuses on seismic analysis alone, rather than looking at how many risks interact with one another. Nevertheless, in order to guarantee sufficient strength, stability, and usability, it is necessary to evaluate structures under various load combinations during practical structural design.A symmetrical G+4 reinforced concrete residential structure was subjected to a multi-hazard structural analysis using ETABS in this research. All loads, including dead and live loads, seismic and wind loads, are taken into account while analysing the building model in accordance with IS 1893 (Part 1):2002 and IS 875 (Part 3). Presumably, the building is situated in Seismic Zone V, a zone with very strong seismic activity. By using code-based load combinations, ETABS assesses the reaction of structural components by measuring their shear, bending, torsional, axial, and storey drift forces.By comparing the critical beam and column responses at three sample plan locations—corner, center, and edge members—the structural behavior is explored. Because the building is in a high seismic zone and not very tall, most of the member forces are governed by seismic load combinations, according to the findings. Because wind pressure increases with height, the impacts of the wind are less noticeable on lower stories but become more noticeable on higher ones. As a result of the building's regular and symmetrical layout, the structural pressures vary uniformly and predictably across various sites, with a fluctuation of around 10%.Instead of depending on a single governing load instance, the research shows that ETABS is a good platform for multi-hazard analysis and emphasizes the need of taking into account various environmental activities. Under actual loading circumstances, the technique offers a practical way to evaluate the safety and performance of reinforced concrete structures.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

RISK ASSESSMENT OF AN ETABS-BASED MULTI-STOREY RESIDENTIAL REINFORCED CONCRETE STRUCTURE — 科研速览 Science Skim