Is routine chest X-ray necessary after ultrasound-guided TIVAP insertion through the internal jugular vein?
Kübra Gözaçık Karakoç, Tamer Cebe, Anıl AkbaŞ, Bekir Yıldız, Gökhan Karakoç
Department of Cardiovascular Surgery, Batman Training and Research Hospital, Batman, Turkey. Email: drgozacikkubra@gmail.com. · Department of Cardiovascular Surgery, Batman Training and Research Hospital, Batman, Turkey.
Key points
From the paper's conclusion- Routine post-procedural chest X-ray identified catheter tip malpositioning in a subset of patients; however, these findings did not alter clinical management in the absence of port dysfunction. Selective imaging in patients with failed port functionality may safely reduce unnecessary radiation exposure and healthcare costs without compromising outcomes.
Abstract
OBJECTIVES: This study evaluated routine chest X-ray necessity following ultrasound-guided totally implantable venous access port (TIVAP) placement via internal jugular vein. MATERIALS AND METHODS: We retrospectively analysed 97 adults who underwent ultrasound-guided TIVAP placement at a tertiary cardiovascular surgery clinic in Eastern Turkey (December 2023-December 2024). Intraoperative port functionality (blood aspiration/fluid infusion) and postprocedural chest X-ray findings were assessed. Catheter positions were categorised as optimal, suboptimal, or malpositioned. RESULTS: Among 97 patients (56.7% male; mean age 57.4 ± 15.0 years), pneumothorax occurred in one patient (1.0%), requiring intervention. Nineteen patients (19.6%) had suboptimal/malpositioned catheter tips but required no corrective action as port functionality remained intact. Radiographic findings prompted intervention in only one patient (1.0%). CONCLUSIONS: Routine post-procedural chest X-ray identified catheter tip malpositioning in a subset of patients; however, these findings did not alter clinical management in the absence of port dysfunction. Selective imaging in patients with failed port functionality may safely reduce unnecessary radiation exposure and healthcare costs without compromising outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fluoroscopic Catheter-Tip Positioning During Internal Jugular TIVAD Placement in Breast Cancer: A Two-Center Retrospective Cohort Study.Diagnostics (Basel, Switzerland) · 2026
- Comparative safety outcomes of three venous access routes for totally implantable venous access port placement and exploratory assessment of pre-removal catheter-related thrombosis in breast cancer patients.Frontiers in oncology · 2026
- Effects of ultrasound-guided ipsilateral internal jugular vein compression on catheter malposition during ultrasound-guided right infraclavicular subclavian venous catheterisation: a randomised controlled trial.Anaesthesia · 2026
- Fluoroscopy-guided transfemoral pigtail catheter repositioning of malpositioned totally implantable venous access port catheters: a retrospective single-center study.Quantitative imaging in medicine and surgery · 2026
- Image-Guided TIVAP by Interventional Radiologists: A Single-Center Cohort Study Using Institutional Surgical Benchmarks.Journal of clinical medicine · 2026
- Delayed innominate vein perforation and massive hemothorax following left-sided PICC placement: A case report.Medicine · 2026