Image-Guided TIVAP by Interventional Radiologists: A Single-Center Cohort Study Using Institutional Surgical Benchmarks.
Nour Maalouf, Mazen Abou Mrad, Fiona Mankertz, Reza Dehdab, Isabelle Schöpper, Rosa Alba Pugliesi, Saif Afat, Jonas C Apitzsch
Department of Radiology, Tübingen University Hospital, 72076 Tübingen, Germany. · Department of Anesthesiology and Intensive Care, Tübingen University Hospital, 72076 Tübingen, Germany.
Key points
From the paper's conclusion- Conclusions: IR-guided TIVAP implantation required fewer personnel and was associated with lower observed procedural costs and shorter recorded procedure times relative to institutional surgical benchmarks.
Abstract
Background/Objectives: To evaluate the resource utilization, procedural costs, procedure time, and intraprocedural outcomes of interventional radiology (IR)-guided totally implantable venous access port (TIVAP) placement and contextualize these findings using institutional surgical benchmarks. Methods: We conducted a single-center study between March 2020 and March 2024 that included 93 patients requiring TIVAP placement for chemotherapy. All ports were inserted under ultrasound and fluoroscopic guidance in an angiography suite. Surgical insertions using a cephalic vein cut-down under anesthesia were used as a comparator. Data collected included number of consent forms, staffing, procedure duration, material and medication utilization, and procedural costs obtained from hospital financial records. Descriptive statistics were used to summarize outcomes. Results: IR-guided TIVAP insertion required one combined consent form and two personnel, compared with two consent forms and four personnel for the surgical workflow. The average procedural cost in the angiography suite was €168.16 versus an institutional surgical benchmark of €407.90, representing a 58.8% lower observed cost. The recorded average procedure time was 45 min for IR versus 85 min for the surgical benchmark. Material costs were comparable, except for intravenous anesthetic agents used in the operating room. No intraprocedural complications occurred among the 93 IR cases. Conclusions: IR-guided TIVAP implantation required fewer personnel and was associated with lower observed procedural costs and shorter recorded procedure times relative to institutional surgical benchmarks. The absence of a patient-level surgical comparator and long-term follow-up limits conclusions regarding comparative safety and clinical outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Image-guided same-session conversion of non-tunneled central venous catheters to implantable ports through the existing venous entry: a retrospective cohort studyFrontiers in Oncology · 2026
- Analgesic Effectiveness of Ultrasound-Guided PECS II Block in Implantable Venous Port Catheter Placement: A Retrospective Comparative Study.Medicina (Kaunas, Lithuania) · 2026
- Fluoroscopic Catheter-Tip Positioning During Internal Jugular TIVAD Placement in Breast Cancer: A Two-Center Retrospective Cohort Study.Diagnostics (Basel, Switzerland) · 2026
- The effect of virtual reality on anxiety and pain in patients undergoing totally implantable venous access port: a systematic review and meta-analysis.Frontiers in medicine · 2026
- Integrating Extended Reality into Interventional Radiology: A Single Center Feasibility Study of a Virtual Ruler for PICC Line Placement.Journal of vascular and interventional radiology : JVIR · 2026
- Is routine chest X-ray necessary after ultrasound-guided TIVAP insertion through the internal jugular vein?Cardiovascular journal of Africa · 2026