Clinical and experimental rheumatology

Detection of myositis in a rat model by shear wave elastography and dispersion imaging based on muscle viscoelasticity.

Yuwei Xin, Mingxu Li, Danan Li, Yiqun Liu, Wenxue Li, Jiaan Zhu

Department of Ultrasound, Peking University People's Hospital, Beijing, China. · Department of Ultrasound, Peking University People's Hospital, Beijing, China. zhujiaan@pkuph.edu.cn.

Preclinical

Key points

From the paper's conclusion
  • SWDI and SWE are valuable tools for assessing inflammatory lesions in skeletal muscle and evaluating myositis severity.

Abstract

OBJECTIVES: This study aimed to assess the feasibility and diagnostic effectiveness of shear wave dispersion imaging (SWDI) and shear wave elastography (SWE) in evaluating myositis through the development of an experimental autoimmune myositis (EAM) rat model. METHODS: EAM was induced in 48 female Lewis rats by immunisation with rabbit skeletal muscle homogenate, while 8 normal ratswere included as a control group. Throughout the study period, 8 EAM rats were randomly selected weekly from the initial immunisation to the sixth immunisation for clinical monitoring, serological analysis, muscle SWDI and SWE assessments, and muscle histopathology examination. The severity of EAM was determined based on clinical observations, serological findings, and muscle histopathology grading. Additionally, correlation analyses were conducted to assess the relationship between shear wave dispersion slope (SWDS) and shear wave speed (SWS) with muscle pathology. RESULTS: After 4 weeks post-immunisation, clinical scores and serum CK levels peaked in EAM rats. Histological analysis revealed extensive muscle fiber degeneration, necrosis, inflammatory cell infiltration and interstitial vessel involvement. A strong positive correlation was observed between CK (r=0.729, p<0.001) and clinical scores (r=0.753, p<0.001) with the pathology grading. The SWDS and SWS of the muscles in EAM rats were significantly lower compared to normal controls in both transverse and longitudinal sections, decreasing with the progression of myositis (p<0.05). A significant negative correlation was found between shear wave parameters and muscle pathology grading (p<0.001). SWDS and SWS demonstrated high diagnostic accuracy for EAM, with the AUC of SWDS being higher in transverse sections, while the AUC of SWS being higher in longitudinal sections, although the difference was not statistically significant (p>0.05). CONCLUSIONS: SWDI and SWE are valuable tools for assessing inflammatory lesions in skeletal muscle and evaluating myositis severity.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers