Shear wave elastography in infantile fibromatosis colli: associations with clinical severity and short-term outcomes.
Yu Sung Yoon, Eun Kyung Khil, Sang Won Jo, Yeong Seo Yoo, Hyeoncheol Hwang
Department of Radiology, School of Medicine, Kyungpook National University, Kyungpook National University Hospital, Daegu, Korea. · Department of Radiology, Fastbone Orthopedic Hospital, Hwaseong, Korea.
Key points
From the paper's conclusion- In infantile fibromatosis colli, longitudinal extent and E-ratio were associated with baseline clinical severity. SWE-derived stiffness measures, particularly E-ratio, were associated with short-term outcomes.
Abstract
PURPOSE: This study evaluated shear wave elastography (SWE) in infants with fibromatosis colli by assessing the associations of ultrasonography (US) and SWE with clinical severity and outcomes. METHODS: This retrospective study included infants with fibromatosis colli who underwent US with SWE between June 2019 and December 2021. Lesion size and longitudinal extent of sternocleidomastoid involvement were measured, with extent categorized using a four-point scale (<25%, 25%-49%, 50%-74%, and ≥75%). SWE parameters included mean and median elasticity and the elasticity ratio (E-ratio; mass/normal muscle). Clinical severity was classified as mild or severe and 3-month outcomes as improved or non-improved. Associations of imaging parameters with clinical severity and outcomes were analyzed. RESULTS: Thirty-five infants (mean age, 1.1±1.4 months; 19 male infants) were included; 21 had mild and 14 severe disease. Of these, 29 underwent approximately 3-month follow-up, with 16 classified as improved and 13 as non-improved. Baseline extent scores and E-ratios were higher in the severe group (P=0.009 and P=0.004, respectively) and correlated with clinical severity (r=0.50, P=0.002; r=0.41, P=0.016, respectively). The non-improved group had higher baseline mean and median elasticity (24.35/23.70 vs. 18.02/16.61 kPa, P=0.037/P=0.032) and a higher E-ratio (3.09 vs. 1.90, P=0.002). The E-ratio had an area under the receiver operating characteristic curve of 0.81 and remained associated with non-improvement after age adjustment (odds ratio, 3.73; 95% confidence interval, 1.57 to 12.29; P=0.009). CONCLUSION: In infantile fibromatosis colli, longitudinal extent and E-ratio were associated with baseline clinical severity. SWE-derived stiffness measures, particularly E-ratio, were associated with short-term outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Novel evaluation of the sternocleidomastoid muscle of head and neck cancer patients using shear wave elastography: A preliminary exploratory pilot study.Ultrasound (Leeds, England) · 2026
- Histopathologic determinants of shear-wave elastography stiffness in soft-tissue sarcomas.Ultrasonography (Seoul, Korea) · 2026
- Detection of myositis in a rat model by shear wave elastography and dispersion imaging based on muscle viscoelasticity.Clinical and experimental rheumatology · 2026
- Shear Wave Elastography for Non-Invasive Assessment of Skin Involvement in Systemic Sclerosis.Diagnostics (Basel, Switzerland) · 2026
- Ultrasound Shear-Wave and Strain Elastography for Differentiating Morton's Neuroma from Intermetatarsal Bursitis.Life (Basel, Switzerland) · 2026
- Shear-wave elastography in rotator cuff tears: a systematic review of measurement properties, tissue-stiffness findings, and clinical interpretability.European radiology · 2026