Evaluating low-cost NDIR CO 2 sensors for atmospheric observations in rural settings
Olalekan A. M. Popoola, Paolo Cicuta, Rachel H. Georgiou, Lawrence Tom, Ray Freshwater, Kelsey Leet, Chiara Giorio
Key points
From the paper's conclusion- Overall, this study establishes that field calibrated low-cost CO 2 sensors and sensor networks can provide reliable, long-term atmospheric monitoring in rural environments when sensor enclosures are appropriately designed to ensure adequate ventilation and air exchange, thereby preventing moisture accumulation.
Abstract
Most research and monitoring activities involving low-cost atmospheric sensors (LC) have traditionally focused on urban environments, where air quality is a pressing concern. However, an emerging area of research is their application in rural landscapes, where land use is a key determinant of climate change and net zero outcomes, directly influencing greenhouse gas emissions, carbon sequestration, and ecosystem functioning. In this study, we examine the use of LC non-dispersive infrared (NDIR) CO 2 sensors to monitor atmospheric mixing ratios in agricultural settings. We present a data analysis framework that addresses errors associated with factory auto-baseline correction and, crucially, accounts for the influence of environmental parameters such as temperature and pressure. This approach leads to improved sensor performance. Results from deployments in both rural and urban environments demonstrate strong agreement with reference-grade instruments, as shown by the root mean square error (RMSE) and coefficient of determination ( R 2 ). Improvements of RMSE from 10 to 4 ppm in winter and 5 to 4 ppm in summer, with corresponding improved R 2 from 0.85 to 0.98 in winter and 0.86 to 0.97 in summer were obtained when compared to a simple scaling correction of the out-of-box data. Our study shows that corrected data not only reproduced the seasonal profile associated with rural emissions, but it also captured the diurnal variability, sometimes characterised by CO 2 change of up to 50 ppm, which is more than three times the typical change in the urban environment (15 ppm). Overall, this study establishes that field calibrated low-cost CO 2 sensors and sensor networks can provide reliable, long-term atmospheric monitoring in rural environments when sensor enclosures are appropriately designed to ensure adequate ventilation and air exchange, thereby preventing moisture accumulation. The observations obtained provide valuable inputs for developing analytical methodologies and offer actionable insights into the influence of rural land-use practices on climate.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Limitations of Environmental Extrapolation in Low-Cost Carbon Monoxide and Fine Particulate Matter Sensors.Sensors (Basel, Switzerland) · 2026
- Development and LoRa-based implementation of a ZIF-8 chemiresistive CO2 sensor for air quality monitoring.RSC advances · 2026
- How Accurate Are Low-Cost Air Quality Sensors? A 10-Month Study of Three-Tier Comparison with Three Calibration Methods and Cross-Site Transferability.Sensors (Basel, Switzerland) · 2026
- UAV-based method for measuring CO 2 emissions in forest ecosystemsAtmospheric Measurement Techniques · 2026
- Airborne performance assessment of the DLR MIRO MGA 3 quantum cascade laser spectrometer for fast N 2 O measurementsAtmospheric measurement techniques · 2026
- ACROPOLIS: Munich urban CO₂ sensor networkAtmospheric measurement techniques · 2026