Development and LoRa-based implementation of a ZIF-8 chemiresistive CO2 sensor for air quality monitoring.
Natraj Athreya A S, Fouziya Sulthana S
Department of Mechatronics Engineering, College of Engineering and Technology, SRM Institute of Science and Technology Kattankulathur Tamil Nadu 603203 India fouziyas@srmist.edu.in.
Key points
From the paper's conclusion- The ZIF-8/LoRaWAN node therefore offers a low-cost, low-power, non-optical option for indicative indoor CO2 monitoring and ventilation feedback in smart buildings.
Abstract
Elevated indoor carbon dioxide (CO2) levels impair occupant comfort and performance, motivating low-cost, wireless air-quality monitoring (AQM) in enclosed spaces. This paper presents a distributed sensor node architecture combining a fabricated ZIF-8 layer-based chemiresistive CO2 sensor with low-power LoRaWAN communication for real-time, metrologically validated AQM. The node converts film resistance into a CO2 concentration using a single-line calibration against a commercial SCD40 NDIR reference, fitted over 400-1200 ppm (R 2 = 0.995). Eight consecutive gas-exposure cycles on the fully assembled node at a nominal 1000 ppm gave a response of 39.1 ± 0.2%, a response time of 0.80 ± 0.01 s and a recovery time of 1.21 ± 0.02 s (mean ± SD), and a 15-gas selectivity screen gave a CO2 response 4.5-4.7 times that of the strongest interferents (methanol, ethanol) and at least 6.7 times that of every other gas tested. Over a LoRaWAN link at 865 MHz, the node transmitted reliably over an obstructed indoor path of up to 135 m with an average packet loss below 4%. Real-time field trials co-located with the SCD40 at five sites, an ICU ward, a classroom, a lathe workshop, a car cabin and an open-air outdoor reference point, gave 32 individual paired readings within the calibrated 400-1200 ppm range with a mean absolute error of 7.9 ppm, an RMSE of 10.9 ppm and a Bland-Altman bias of +2.2 ppm (95% limits of agreement -19.0 to +23.3 ppm). A GUM-based uncertainty budget gives an expanded uncertainty (k = 2) of approximately ±110-146 ppm for a single reading across this range, dominated by the reference-instrument and humidity-sensor contributions. The ZIF-8/LoRaWAN node therefore offers a low-cost, low-power, non-optical option for indicative indoor CO2 monitoring and ventilation feedback in smart buildings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Desk‐Level CO 2 Sensing for Monitoring Occupancy and Indoor Environmental QualityIndoor Air · 2026
- Real-time breath analysis for COPD risk assessment in smokers using a ZnO/SnO₂ heterojunction sensor integrated with support vector machineScientific Reports · 2026
- Evaluating low-cost NDIR CO 2 sensors for atmospheric observations in rural settingsAtmospheric Measurement Techniques · 2026
- A Fully Integrated Smart Facemask for Ultrafast and Humidity-Resistant Exhaled CO2 Monitoring.ACS sensors · 2026
- Fabrication and Performance Evaluation of a LoRaWAN-Based Wireless Sensor Node for Greenhouse Environmental MonitoringAgriculture · 2026
- Ten questions concerning low-cost indoor air quality sensors: Perspectives from research and practiceBuilding and Environment · 2026