Percutaneous sheathless subclavian intra-aortic balloon pump implantation as a bridge to heart transplantation: a feasibility study.
Krzysztof Szaniewski, Olena Nefodova, Krzysztof Dyrbuś
Silesian Center for Heart Diseases, Zabrze, Poland.
Key points
From the paper's conclusion- Sheathless percutaneous subclavian IABP implantation appears to be a feasible and safe strategy for bridging critically ill patients to definitive therapy. It reduces vascular trauma, facilitates patient mobilization, and allows surgical access to be avoided. Further studies in larger cohorts are warranted to confirm these promising results.
Abstract
INTRODUCTION: Intra-aortic balloon pump (IABP) therapy is a widely used mechanical circulatory support method for patients with advanced heart failure, including those awaiting orthotopic heart transplantation (OHT). Traditional femoral access limits patient mobility and may not be suitable in cases of peripheral artery disease. AIM: This study evaluates the feasibility and safety of a fully percutaneous, sheathless IABP implantation via the left subclavian artery as a bridge to transplantation. MATERIAL AND METHODS: Between June and December 2024, 10 patients in critical condition (1 F, 9 M, mean age: 58 years) underwent IABP implantation using ultrasound-guided puncture of the left subclavian artery without surgical exposure. The balloon was inserted sheathless and secured to the chest wall. Device removal was also performed percutaneously with a 6F AngioSeal closure device. RESULTS: Definitive therapy (OHT or LVAD) was achieved in 60% of patients. The mean IABP support duration was 21.6 days (up to 69 days). There were no local access site complications. Two device-related mechanical issues were managed without sequelae. One fatal outcome was potentially related to embolic complications; others were due to progressive multiorgan failure. The subclavian approach preserved femoral access and enabled early mobilization. CONCLUSIONS: Sheathless percutaneous subclavian IABP implantation appears to be a feasible and safe strategy for bridging critically ill patients to definitive therapy. It reduces vascular trauma, facilitates patient mobilization, and allows surgical access to be avoided. Further studies in larger cohorts are warranted to confirm these promising results.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Outcomes and Complications of Axillary Intra-Aortic Balloon Pump Support: A Single-Center Experience.ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2026
- Repositioning Axillary Intra-Aortic Balloon Pumps in Patients Awaiting Heart Transplantation Is Associated With Complications.ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2026
- 293-Day Intra-Aortic Balloon Pump Support as a Bridge to Transplantation in Refractory Heart Failure.JACC. Case reports · 2026
- Bridge to transplant in the contemporary allocation era: a systematic review and meta-analysis of impella versus intra-aortic balloon pumpEuropean Heart Journal · 2026
- First-in-Human Axillary Vein Implantation of a Leadless Pacemaker: Breaking the Access Barrier.JACC. Case reports · 2026
- Concomitant Wire-Loop Repositioning and Transapical Valve Replacement for a Migrated Sutureless Aortic Valve.JACC. Case reports · 2026