Sex-related differences in long-term outcomes of drug-coated balloons versus thin-strut drug-eluting stents in the treatment of in-stent restenosis (DCB-DRAGON Registry).
Rafał Januszek, Michał Tarnowski, Paweł Pawlus, Sylwia Iwańczyk, Łukasz Kuźma, Brunon Tomasiewicz, Piotr Kubler, Maciej Wybraniec,
Faculty of Medicine and Health Sciences, Andrzej Frycz Modrzewski Cracow University, Krakow, Poland. · Department of Cardiology, Holy Spirit Specialist Hospital, Sandomierz, Poland.
Key points
From the paper's conclusion- Sex did not modify the comparative effectiveness of DCB versus thin-strut DES for ISR, on the composite endpoint or on any component; these data do not support sex-based device selection. Wide intervals and differential follow-up establish the absence of detectable heterogeneity rather than equivalence.
Abstract
INTRODUCTION: Drug-coated balloons (DCB) and drug-eluting stents (DES) are established options for coronary in-stent restenosis (ISR); evidence on sex-specific outcomes remains limited. AIM: To determine whether sex modifies the comparative effectiveness of DCB versus thin-strut, second-generation DES in ISR. MATERIAL AND METHODS: Retrospective analysis of 1,317 patients undergoing percutaneous coronary intervention for ISR, 2008-2021. Because 57.6% were censored before 3 years, the primary estimand is the difference in restricted mean survival time (RMST) over 0-3 years for the device-oriented composite endpoint (DOCE). Counterfactual survival was estimated by weighted Kaplan-Meier estimation with entropy-balancing weights within each sex stratum; variance was estimated using bootstrap resampling pooled across 20 imputed datasets by Rubin's rules. RESULTS: Among 395 (30.0%) women and 922 (70.0%) men, 209 DOCE events accrued. Median observation time differed approximately twofold between arms (20.6 vs. 38.7 months in women; 19.7 vs. 39.4 months in men). The RMST difference was -0.047 years (95% CI: -0.579 to +0.486) in women and +0.036 (-0.186 to +0.259) in men, a sex difference of -0.083 years (-0.661 to +0.495; p = 0.78); weighted HRs were 0.76 (0.43-1.34) and 0.73 (0.50-1.07), respectively. No secondary endpoint showed heterogeneity: every uncorrected p exceeded 0.5 and every false-discovery-rate-adjusted value equalled 0.82. Cardiovascular deaths were similar between arms in women (5 vs. 5) and men (16 vs. 15); weighted HRs for all-cause mortality were 1.03 (0.39-2.72) and 0.78 (0.42-1.46), respectively. CONCLUSIONS: Sex did not modify the comparative effectiveness of DCB versus thin-strut DES for ISR, on the composite endpoint or on any component; these data do not support sex-based device selection. Wide intervals and differential follow-up establish the absence of detectable heterogeneity rather than equivalence.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Long-term outcomes following DCB versus thin-strut DES for treatment of in-stent restenosis in acute coronary syndromeEuropean Heart Journal · 2026
- Ultrathin-strut drug-eluting stents are associated with lower revascularization rates than drug-coated balloons in non-focal in-stent restenosis.Frontiers in cardiovascular medicine · 2026
- Use of Paclitaxel-Coated Balloons in the United States: Early Results From the AGENT Postapproval StudyCirculation Cardiovascular Interventions · 2026
- Clinical Outcomes of Drug-Eluting Stents and Drug-Coated Balloons in Tortuous Small Coronary Lesions.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- Outcomes of Drug-Coated Balloon Versus Drug-Eluting Stent for the Treatment of Large De Novo Coronary Lesions.Reviews in cardiovascular medicine · 2026
- Less metal, same outcomes: drug-coated balloon PCI in acute coronary syndrome - real-world registry dataEuropean Heart Journal · 2026