Ultrathin-strut drug-eluting stents are associated with lower revascularization rates than drug-coated balloons in non-focal in-stent restenosis.
Berhan Keskin, Aykun Hakgor, Atakan Dursun, Aysel Akhundova, Umeyir Savur, Ebubekir Yigitbay, Ozlem Onder, Beytullah Cakal,
Department of Cardiology, Istanbul Medipol University, Medipol Mega University Hospital, Istanbul, Türkiye.
Key points
From the paper's conclusion- Ultrathin-strut SES was associated with lower TLR and MACE rates compared with DCB in non-focal DES-ISR, whereas outcomes were comparable in focal ISR. These findings highlight the importance of lesion characteristics and support a tailored approach to ISR management.
Abstract
BACKGROUND: In-stent restenosis (ISR) remains a significant clinical challenge despite advances in drug-eluting stent (DES) technology. Although current guidelines recommend drug-coated balloon (DCB) angioplasty or repeat DES implantation for DES-ISR, real-world data comparing DCB with newer-generation ultrathin-strut sirolimus-eluting stents (SES) are limited. METHODS: This retrospective, single-center study included consecutive patients with stable angina who underwent treatment for DES-ISR using either a paclitaxel-coated DCB or an ultrathin-strut SES between January 2015 and May 2025. The primary outcome was target-lesion revascularization (TLR). Secondary endpoints included major adverse cardiac events (MACE), defined as a composite of all-cause mortality, myocardial infarction, stroke, and TLR. Time-to-event analyses were performed using Kaplan-Meier methods and Cox proportional hazards regression. RESULTS: A total of 205 patients were included (DCB, n = 106; SES, n = 99), with a median follow-up of 863 days. In the overall cohort, TLR rates were comparable between groups. However, in the non-focal ISR subgroup, TLR was significantly higher in the DCB group compared with SES (34.1% vs. 12.7%, p = 0.024). Similarly, MACE rates were higher with DCB in non-focal ISR (39.0% vs. 18.2%, p = 0.041). No differences were observed in focal ISR. Multivariable analysis in the non-focal subgroup identified DCB treatment (HR 3.89, p = 0.006) as independent predictor of TLR. Kaplan-Meier analyses for TLR and MACE consistently demonstrated significantly worse outcomes with DCB in the non-focal ISR subgroup, whereas no significant differences were observed in focal ISR. CONCLUSIONS: Ultrathin-strut SES was associated with lower TLR and MACE rates compared with DCB in non-focal DES-ISR, whereas outcomes were comparable in focal ISR. These findings highlight the importance of lesion characteristics and support a tailored approach to ISR management.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Long-term outcomes following DCB versus thin-strut DES for treatment of in-stent restenosis in acute coronary syndromeEuropean Heart Journal · 2026
- Sex-related differences in long-term outcomes of drug-coated balloons versus thin-strut drug-eluting stents in the treatment of in-stent restenosis (DCB-DRAGON Registry).Postepy w kardiologii interwencyjnej = Advances in interventional cardiology · 2026
- Sirolimus-Eluting Balloon vs Repeat Drug-Eluting Stent or Balloon Angioplasty for Coronary In-Stent RestenosisJournal of the American College of Cardiology · 2026
- Sirolimus- vs. paclitaxel-eluting balloons for the treatment of coronary in-stent restenosis: a systematic review and meta-analysisEuropean Heart Journal Supplements · 2026
- Clinical Outcomes of Drug-Eluting Stents and Drug-Coated Balloons in Tortuous Small Coronary Lesions.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- Acute and long-term safety and efficacy of IVUS-guided drug-coated balloon treatment for carotid in-stent restenosis.Cardiovascular revascularization medicine : including molecular interventions · 2026