Postepy w kardiologii interwencyjnej = Advances in interventional cardiology

Comparison of transcatheter aortic valve replacement performed in a hybrid operating room versus a catheterization laboratory.

Ronan Canitrot, Vincent Bataille, Frédéric Bouisset, Francisco Campelo-Parada, Didier Carrié, Thibault Lhermusier, Clément Servoz

Department of Cardiology, University Hospital of Toulouse, Toulouse, France.

Key points

From the paper's conclusion
  • Regarding the composite safety and efficacy endpoints, no statistically significant between-group differences were detected in this unadjusted single-center cohort between patients undergoing TF-TAVR in a cath lab and those treated in a hybrid OR. These data suggest that performing TF TAVR in the cath lab can achieve high safety and effectiveness outcomes.

Abstract

INTRODUCTION: Transcatheter aortic valve replacement (TAVR) can be performed in a catheterization laboratory (cath lab) or in a hybrid operating room (hybrid OR). AIM: The objective of this study was to compare the safety of patients undergoing TAVR in a hybrid OR with those undergoing TAVR in a cath lab. MATERIAL AND METHODS: The primary endpoint was a composite safety endpoint, which includes freedom from all-cause in-hospital mortality, stroke, major vascular complications (VARC ≥ 2), aortic regurgitation (grade ≥ 2), new pacemaker implantation, emergent surgery, annulus rupture, tamponade, or stent femoral implantation. The two secondary endpoints consisted of technical failure criteria and device failure criteria, at hospital discharge. RESULTS: A total of 286 patients were included, 143 undergoing TF TAVR in the cath lab and 143 in a hybrid OR. Regarding the safety primary endpoint, there was no significant difference between the groups: 75.3% in the cath lab group versus 71.1% in the hybrid OR group (p = 0.421). There was also no significant difference in the technical failure criteria (3.5% in the cath lab group versus 4.2% in the hybrid OR group; p = 0.758) and device failure criteria (20.6% in the cath lab group versus 17.6% in the hybrid OR group; p = 0.526). CONCLUSIONS: Regarding the composite safety and efficacy endpoints, no statistically significant between-group differences were detected in this unadjusted single-center cohort between patients undergoing TF-TAVR in a cath lab and those treated in a hybrid OR. These data suggest that performing TF TAVR in the cath lab can achieve high safety and effectiveness outcomes.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers