Outcomes of Transcatheter Aortic Valve Replacement for Aortic Regurgitation in LVAD Patients: The JENA-VAD Study.
Ravi Ramana, Nir Uriel, Pradeep Yadav, Lowell Satler, Lauren S Ranard, Toby Rogers, Ron Waksman, Itsik Ben-Dor,
Division of Cardiology, Heart Care Centers of Illinois, Palos Park, Illinois USA; Divisions of Cardiology and Cardiothoracic Surgery, Advocate Christ Medical Center, Oak Lawn, Illinois USA. · Division of Cardiology, Columbia University Irving Medical Center/NewYork-Presbyterian Hospital, New York, New York USA.
Key points
From the paper's conclusion- Transcatheter valve replacement using a dedicated system in LVAD patients was feasible with high technical and device success and without early death, stroke, or moderate or severe residual AR. Leaflet thickening or thrombosis, detected on clinically indicated CT imaging, occurred in 22%, representing a lower bound. Follow-up is ongoing to inform longer-term safety and effectiveness. (Transcatheter Aortic Valve Replacement Using the JenaValve Trilogy Heart Valve System for Clinically Significant Aortic Regurgitation in Patients With Left Ventricular Assist Devices [LVAD]; NCT06594705).
Abstract
BACKGROUND: Aortic regurgitation (AR) during left ventricular assist device (LVAD) support causes recurrent heart failure. Surgery is high risk and stenosis-designed valves anchor poorly in noncalcified anatomy. OBJECTIVES: The goal of this study was to evaluate early outcomes of the AR-specific Trilogy transcatheter heart valve for LVAD-associated AR. METHODS: JENA-VAD is a prospective, multicenter, single-arm investigational device exemption study. An independent committee adjudicated endpoints using VARC-3 (Valve Academic Research Consortium-3) definitions. The primary efficacy endpoint was the VARC-3 device success composite adapted for LVAD support, and the primary safety endpoint was the VARC-3 early safety composite. RESULTS: Fifty patients were treated (mean age 69.2 years; 40% female). Median follow-up was 105 days (range 27 to 577 days). Technical and device success were 96.0% (95% CI: 86.3-99.5). Freedom from any component event of the VARC-3 early safety composite was 90.0% (95% CI: 78.2-96.7). At 30 days, 7 VARC-3 safety events occurred in 5 patients: type 2 to 4 bleeding (n = 2), major vascular complications (n = 2), device-related peripheral interventions (n = 2), and new pacemaker (1 of 7 without prior pacing; 14.3%). There were no strokes or myocardial infarctions. Two transient ischemic attacks occurred in patients without valve abnormalities. Beyond 30 days, cardiovascular death occurred in 1 patient (day 86). Follow-up computed tomography (CT) imaging or transesophageal echocardiography was obtained in 12 patients, and 11 (including 3 within 30 days) had leaflet thickening or thrombosis, including all patients who underwent CT. The remaining 38 patients did not have postprocedure imaging. Two of these events were symptomatic: valve thrombosis and a transient ischemic attack (day 116), and prosthetic AR that required valve-in-valve implantation (day 146) and subsequent heart transplantation. In exploratory analyses, NYHA functional class at 30 days was I or II in 72.3% (34 of 47) and Kansas City Cardiomyopathy Questionnaire overall summary score rose 11.5 ± 21.5 points (n = 44). CONCLUSIONS: Transcatheter valve replacement using a dedicated system in LVAD patients was feasible with high technical and device success and without early death, stroke, or moderate or severe residual AR. Leaflet thickening or thrombosis, detected on clinically indicated CT imaging, occurred in 22%, representing a lower bound. Follow-up is ongoing to inform longer-term safety and effectiveness. (Transcatheter Aortic Valve Replacement Using the JenaValve Trilogy Heart Valve System for Clinically Significant Aortic Regurgitation in Patients With Left Ventricular Assist Devices [LVAD]; NCT06594705).
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Early Multicenter Outcomes of Dedicated Transcatheter Aortic Valve Replacement for Left Ventricular Assist Device-Associated Pure Aortic Regurgitation.Artificial organs · 2026
- Clinical Outcomes of a Dedicated TAVR Device for Native Aortic Regurgitation: Insights From a Multicenter Real-World Experience.Circulation. Cardiovascular interventions · 2026
- Dedicated versus non-dedicated transcatheter valves for pure native aortic regurgitation: a single-centre experienceNetherlands Heart Journal · 2026
- Aortic valve anatomy and feasibility of transcatheter bioprosthetic valve implantation in isolated aortic regurgitationEuropean Heart Journal · 2026
- Transcatheter Aortic Valve Replacement in Patients With Symptomatic, Severe Aortic Regurgitation: 1-Year Outcomes of the J-Valve Transfemoral Early Feasibility Study.Journal of the Society for Cardiovascular Angiography & Interventions · 2026
- Transcatheter Aortic Valve Implantation for Pure Native Aortic Regurgitation: A Comprehensive State-of-the-Art Review.Reviews in cardiovascular medicine · 2026