Turkish journal of pharmaceutical sciences

Establishment and Validation of a Stability-Indicating RP-HPLC Protocol for Mavacamten in Oral Capsule Preparations.

Pratibha Atul Daroi, Pranjali Patil, Vijay Munipalli, Bhushan Sonawane

LSHGCT's Gahlot Institute of Pharmacy, Department of Pharmaceutical Quality Assurance, Koparkhairne, Navi Mumbai, Maharashtra, India. · Central Drugs Testing Laboratory, Zonal FDA Bhavan, Department of Analytical Research and Development Mumbai, Maharashtra, India.

Key points

From the paper's conclusion
  • The developed method is precise and reliable, and offers a practical tool for routine quality control and future research, while emphasising the need for controlled storage conditions to ensure long-term drug integrity.

Abstract

OBJECTIVES: Mavacamten (MYK-461), approved for hypertrophic cardiomyopathy, is a cardiac myosin inhibitor. At present, no pharmacopoeial method for its quantification has been reported. Our study was designed to establish a validated stability-indicating reverse-phase high-performance liquid chromatography method to quantify MYK-461 in its capsule formulation. MATERIALS AND METHODS: For chromatographic separation, an Inertsil ODS-3V C18 column (250 × 4.6 mm, 5 μm) with the mobile phase of 0.1% trifluoroacetic acid and acetonitrile (50:50 v/v) was used. The flow rate (1.0 mL/min), column temperature (35 °C), injection volume (10 μL), total run time (10 minutes), and detection wavelength (269 nm) were applied. RESULTS: The validated method showed precision, accuracy, and robustness, with relative standard deviation < 2% and recovery of 100.5%. Linearity was observed over the range 5-75 μg/mL (r = 0.9994). We achieved a clear, well-resolved separation of MYK-461 from impurities, with estimated limit of detection (1.58 μg/mL) and limit of quantification (4.8 μg/mL). In forced degradation studies, we observed the highest degradation under acidic conditions (10.37%), while minimal degradation under photolytic (0.93%), thermal (1.66 %), oxidative (2.56%), and alkaline (4.19%) conditions. CONCLUSION: The developed method is precise and reliable, and offers a practical tool for routine quality control and future research, while emphasising the need for controlled storage conditions to ensure long-term drug integrity.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers