Development and validation of an RP-HPLC method for the quantification of impurities of icatibant injection in finished formulations-identification and characterization of its impurities via LC-HRMS.
Sivaji Maganti, Suryakala Duvvuri, Ameer Khan Shaik, Hari Satyanarayana Raju Danthuluri, Simhachalam Pydi
Department of Chemistry, GITAM Deemed to be University, Visakhapatnam, Andhra Pradesh, India. · Eugia Pharma Research Centre, Sangareddy (Dist.), Telangana, India.
Key points
From the paper's conclusion- Specific unidentified "Impurity at RRT about 0.92" (D-Tic (O) 8-10 Icatibant), "Impurity at RRT about 1.15," "Impurity at RRT about 1.24," and "Impurity at RRT about 0.57" were identified and liquid chromatography-high resolution mass spectrometry technique was used for their characterization.
Abstract
In the present study, an efficient reverse-phase high-performance liquid chromatography method was developed for the quantification of impurities of icatibant (IBT) injection in finished formulations. The stationary phase employed is Kromasil 100 C18 with dimension of (150 × 4.6) mm, 3.5 µm. A 0.05 M KH2PO4 (pH 2.5) and methanol in the ratio of (90:10%v/v) was used as eluent A and 0.05 M KH2PO4 (pH 2.5) and methanol in the ratio of (70:30%v/v) was used as eluent B pumped through 1.0 mL/min flow rate using photodiode array detector at 210 nm. The IBT injection was analyzed under various degradation conditions, including acid, base, peroxide, photolytic, and thermal, were evaluated using a present proposed developed method. The method validation was carried out based on International Conference on Harmonization guidelines, by evaluating several key parameters. The observed limit of detection values were 0.066, 0.165, 0.165, 0.197, 0.134, and 0.493 μg/mL, the observed limit of quantification values were 0.201, 0.501, 0.500, 0.598, 0.406, and 1.495 μg/mL for icatibant (7-10), Des-Pro-Impurity, Des-Arg-impurity, Des-D-Arg-impurity, D-Tic (O) 8-10 icatibant and icatibant (1-6), respectively. The average recovery percentages of impurities of IBT injection were found to be 87.4% to 108.2%. The established methodology demonstrated linearity across a concentration interval of 0.020 to 34.73μg/mL for IBT and its impurities. Specific unidentified "Impurity at RRT about 0.92" (D-Tic (O) 8-10 Icatibant), "Impurity at RRT about 1.15," "Impurity at RRT about 1.24," and "Impurity at RRT about 0.57" were identified and liquid chromatography-high resolution mass spectrometry technique was used for their characterization. This method was assessed and confirmed to be more reliable for quantifying impurities of IBT injections.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Establishment and Validation of a Stability-Indicating RP-HPLC Protocol for Mavacamten in Oral Capsule Preparations.Turkish journal of pharmaceutical sciences · 2026
- Stability indicating green HPLC method for Imeglimin hydrochloride determination in pharmaceutical tablets with comprehensive assessmentScientific Reports · 2026
- Development and Validation of an Analytical Quality by Design‐Based Robust Liquid Chromatography Method for Determination of Eight Process and Degradation Impurities in Corticosteroid Drug ProductSEPARATION SCIENCE PLUS · 2026
- Method Development and Validation of Promethazine HCl by Using RP-HPLC and Its Forced Degradation Studies.Assay and drug development technologies · 2026
- Eco-friendly stability-indicating HPLC method development, validation, and LC-MS-based characterization of degradation products of the polar drug imeglimin.Journal of pharmaceutical sciences · 2026
- Simultaneous ecofriendly HPLC determination of clotrimazole, miconazole, metronidazole, and lidocaine in pharmaceutical dosage formsBMC Chemistry · 2026