Ultrasound-guided marker placement and blue dye staining for sentinel lymph node biopsy in early-stage breast cancer.
Yongping Liang, Juan Zhang, Yimiao Wang, Yang Zhang, Hao Dai, Yang Wang, Jianglun Shen, Runxue Jiang,
Tangshan People's Hospital, North China University of Science and Technology, Department of Ultrasound, Tangshan, China. · Tangshan People's Hospital, North China University of Science and Technology, Department of Breast Surgery, Tangshan, China.
Key points
From the paper's conclusion- US-guided localization combined with blue dye concurrently may be a satisfied option for SLNB detection.
Abstract
PURPOSE: Ultrasound (US)-guided marker placement is an emerging method for sentinel lymph node biopsy (SLNB), and this study aimed to investigate the concordance between US-guided marker placement for peri-foraminal lymph nodes (LNs) in the axillary cribriform fascia and blue dye-stained SLNs, especially the utility of the two concurrent labeling methods for SLNB in patients with early-stage breast cancer. METHODS: Female patients with clinically staged T1-2N0M0 breast cancer were enrolled. Patients received US-guided marker placement on the day before surgery, followed by blue dye staining. SLN biopsy was performed on the blue dye-stained LNs first and then on the US-guided markers. RESULTS: A total of 96 eligible patients were enrolled. The detection rates of US-guided localization, blue dye, and their combination were 100.0%, 95.8%, and 100.0%, respectively. Among the 92 patients with blue dye staining, US-guided markers were found in blue-stained LNs from 91 patients (concordant) but failed in 1 patient (non-concordant); among the 4 patients without blue-stained LNs. US-guided markers were found in all 4 patients (non-concordant), resulting in a general concordance rate of 94.8% (91/96). Notably, among the 92 patients with blue dye staining, 23 had LN metastasis diagnosed through SLNB, whereas among the 4 patients without blue-stained LNs, the SLNB was performed based on US-guided markers, which revealed 3 patients with LN metastasis and 1 without. Moreover, combining the two labeling methods concurrently identified 26 patients with LN metastasis. CONCLUSION: US-guided localization combined with blue dye concurrently may be a satisfied option for SLNB detection. CLINICAL SIGNIFICANCE: US-guided localization combined with blue dye offers an accessible, anatomically grounded, and radiation-free strategy for optimizing the SLNB procedure, especially in settings where radioactive isotopes are not available.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Use of indocyanine green fluorescence versus patent blue V dye for sentinel lymph node biopsy in early breast cancer, a randomized controlled trial.Journal of the Egyptian National Cancer Institute · 2026
- Contrast-Enhanced Ultrasound Combined with Methylene Blue for Sentinel Lymph Node Biopsy After Neoadjuvant Chemotherapy in Patients with Initially cN1 Breast Cancer: A Multicenter Prospective Cohort Study.Cancers · 2026
- Outcomes of methylene blue single-dye sentinel lymph node biopsy in early breast cancer: a retrospective cohort study from a resource-limited tertiary centreWorld Journal of Surgical Oncology · 2026
- A Multicenter Non‐Inferiority Randomized Controlled Trial of Sentinel Lymph Node Biopsy in Early Breast Cancer: Conventional Dual Tracer Versus Superparamagnetic Iron OxideWorld Journal of Surgery · 2026
- Technetium-99m stannous phytate versus technetium-99m sulfur colloid for sentinel lymph node mapping in breast cancer: A single-center retrospective study.Medicine · 2026
- Feasibility of a standardized pathological protocol for lymphatic basin evaluation during sentinel node navigation surgery in early gastric cancer: preliminary results from the FLECSS trial.Journal of gastrointestinal oncology · 2026