Standardised versus visual assessment of device success after percutaneous coronary intervention.
Asahi Oshima, Pruthvi C Revaiah, Nozomu Kanehama, Adrian Wlodarczak, Helge Möllmann, Raul Moreno, Milosz Dziarmaga, Manel Sabaté,
CORRIB Research Centre for Advanced Imaging and Core Laboratory, University of Galway, Galway, Ireland. · Division of Cardiology, Copper Health Centre Inc., Lubin, Poland.
Key points
From the paper's conclusion- In this prespecified lesion-level substudy, standardised assessment using the EAPCI device success algorithm with core lab QCA reclassified a substantial proportion of operator-adjudicated successes and identified lesions at higher 1-year LOCE risk. (ClinicalTrials.gov: NCT04390672).
Abstract
BACKGROUND: The European Association of Percutaneous Cardiovascular Interventions (EAPCI)-endorsed algorithm for defining device success has not yet been prospectively tested against standardised quantitative coronary angiography (QCA) by a core lab. AIMS: We sought to assess whether visually evaluated device success by the operator at the end of percutaneous coronary intervention (PCI) aligns with the EAPCI-endorsed standardised definition adjudicated by the core lab and to evaluate its association with clinical outcomes. METHODS: This prespecified analysis of the Multivessel TALENT trial included 1,548 patients with three-vessel disease randomised to treatment with either Supraflex Cruz or SYNERGY stents. PCI was attempted in 4,052 lesions. The core lab assessed post-PCI residual in-stent percentage diameter stenosis (%DS) by QCA (target <20%) and exploratory delta (Δ) angiography-derived fractional flow reserve (angio-FFR) across the stent(s) (target <0.05). Device success was evaluated using the site-reported data (visual evaluation of in-stent %DS), core lab QCA, core lab angio-FFR, and combined core lab QCA+angio-FFR. The lesion-oriented composite endpoint (LOCE; comprising cardiovascular death, target vessel myocardial infarction, or target lesion revascularisation) was assessed at 1 year. RESULTS: Site-reported device success was 97.4%. Core lab definitions yielded lower rates: 93.8% for Δangio-FFR <0.05, 88.0% for residual %DS <20%, and 83.2% for QCA+angio-FFR (all p<0.001 vs site report after Bonferroni correction). Lesions not meeting QCA-based device success had a higher incidence of LOCE than those meeting the definition (12.0% vs 9.1%; log-rank p=0.041). Device success and LOCE rates did not differ between the two stents for any definition. CONCLUSIONS: In this prespecified lesion-level substudy, standardised assessment using the EAPCI device success algorithm with core lab QCA reclassified a substantial proportion of operator-adjudicated successes and identified lesions at higher 1-year LOCE risk. (ClinicalTrials.gov: NCT04390672).
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Prospectively applied EAPCI device success algorithm, comparison of angiography-derived FFR guided and usual care, and association with 1-year lesion-oriented clinical endpoints: the PIONEER IV trialEuropean Heart Journal · 2026
- A comparison between visual, robotic, and intracoronary imaging lesion length assessment during robotic-assisted percutaneous coronary intervention.The Journal of invasive cardiology · 2026
- Impact of Intravascular Imaging on Clinical Outcomes in Focal Versus Diffuse Coronary Artery DiseaseCirculation Cardiovascular Interventions · 2026
- QFR-guided versus IVUS-guided with QFR confirmation for drug-coated balloon treatment of non-complex coronary lesions: a single-centre pilot randomised trialBMC Cardiovascular Disorders · 2026
- Repeatability and quality assessment of QFR in the FAVOR III Europe trial: the REPEAT-QFR studyEuroIntervention · 2025
- Prognostic impact of intravascular imaging in percutaneous coronary intervention according to procedural complexity.AsiaIntervention · 2026