Comparison of self-expanding transcatheter heart valves for aortic stenosis: the multicentre, randomised, controlled, non-inferiority DOUBLE-CHOICE trial
Hans-Josef Feistritzer, Philipp Lauten, Tanja K. Rudolph, Volker Rudolph, Tobias Geisler, Steffen Massberg, Matti Adam, Stephan Baldus,
Leipzig Heart Institute · Zentralklinik Bad Berka
Key points
From the paper's conclusion- We aimed to evaluate the safety and efficacy of transcatheter aortic valve implantation (TAVI) using the ACURATE neo2 valve compared with the Evolut platform in selected anatomies.
Abstract
BACKGROUND: Although withdrawn from the market, the specific design of the ACURATE neo2 valve might influence the design of future transcatheter aortic valve platforms. AIMS: We aimed to evaluate the safety and efficacy of transcatheter aortic valve implantation (TAVI) using the ACURATE neo2 valve compared with the Evolut platform in selected anatomies. METHODS: In this investigator-initiated, 2x2 factorial, open-label, randomised, multicentre, non-inferiority trial, patients with symptomatic, severe aortic stenosis were randomised to the ACURATE neo2 or an Evolut PRO/PRO+/FX valve. The primary endpoint was a composite of all-cause mortality, stroke, moderate/severe prosthetic valve regurgitation, and permanent pacemaker implantation at 30 days. Non-inferiority of the ACURATE neo2 to an Evolut valve was tested in the intention-to-treat population (absolute non-inferiority margin of -6%, α of 0.05). RESULTS: At 10 sites in Germany, 835 patients were randomised. Within 30 days, the primary endpoint occurred in 60/389 patients (15.4%) in the ACURATE neo2 group and in 120/395 patients (30.4%) in the Evolut group (rate difference 15.0%, lower boundary of the 1-sided 95% confidence interval [CI]: 10.1%; p for non-inferiority<0.001, 2-sided 95% CI: 9.1-20.7; p for difference<0.001). A permanent pacemaker was implanted in 42/374 patients (11.2%) in the ACURATE neo2 group and in 101/381 patients (26.5%) in the Evolut group (p for difference <0.001). Rates of moderate/severe prosthetic valve regurgitation were low for both valves (1.3% vs 1.7%; p for difference=0.6). CONCLUSIONS: In selected anatomies, TAVI with the ACURATE neo2 was non-inferior to TAVI with an Evolut valve, with significantly lower rates of the primary endpoint, driven by lower permanent pacemaker implantation at 30 days.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Balloon- Versus Self-Expanding Transcatheter Valves for Failed Small Surgical Aortic Bioprostheses: 3-Year Results of the LYTEN TrialCirculation Cardiovascular Interventions · 2026
- Long-Term Outcomes of a Self-Expanding Transcatheter Heart ValveStructural Heart · 2026
- Comparison Between the Acurate Neo and the Acurate Neo 2 Transcatheter Heart Valve System: Impact of Midframe Under-Expansion.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- Mid-term impact of prosthesis-patient mismatch after transcatheter aortic valve implantation using a self-expanding or balloon-expandable transcatheter heart valveEuropean Heart Journal · 2026
- TAVI in low‑risk severe aortic stenosis: evidence, controversies and lifetime treatment strategy.Expert review of cardiovascular therapy · 2026
- Bioprosthetic valve performance of transcatheter aortic valves.EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2026