Five-year analysis: Outcomes and complications following neodymium: yttrium-aluminum-garnet laser posterior capsulotomy.
Nicholas R Stange, Cameron E Paladino, Sean L Edelstein
Department of Ophthalmology, LSU Health Shreveport School of Medicine, Shreveport, LA, USA. · Department of Ophthalmology, Saint Louis University, Saint Louis, MO, USA.
Key points
From the paper's conclusion- Although Nd:YAG laser capsulotomy is generally safe and effective, adverse events disproportionately affected those with risk factors. In low-risk eyes, routine corticosteroid use and early follow-up may be unnecessary.
Abstract
PURPOSE: To evaluate the incidence of complications after neodymium: yttrium-aluminum-garnet (Nd:YAG) laser capsulotomy and propose follow-up based on individual risk factors. METHODS: We conducted a retrospective review of Nd:YAG posterior capsulotomies performed at an academic center from April 2018 to March 2023. Exclusion criteria included anterior, surgical, and repeat capsulotomies. Parameters considered included intraocular pressure (IOP), corrected distance visual acuity, follow-up interval, and use of steroid or IOP-lowering eye drops. Complications within 1 year were analyzed to determine predisposing risk factors and laser parameters used. RESULTS: Of 594 eyes, an adverse event occurred in 43 (7.2%) eyes, including ocular hypertension in 20 (3.4%), iritis in 7 (1.2%), cystoid macular edema in 6 (1%), corneal decompensation in 4 (0.7%), posterior vitreous detachment in 4 (0.7%), and retinal tear or detachment in 3 (0.5%). Of eyes with complications, 38 (88%) had predisposing risk factors. Eyes experiencing complications were more likely to have a 1-week follow-up (P < 0.00005), higher number of Nd:YAG laser spots (P < 0.05), increased power setting (P < 0.05), and greater total power delivered (P < 0.005). No correlation was noted related to use of anti-inflammatory eye drops following laser (P = 0.63). CONCLUSION: Although Nd:YAG laser capsulotomy is generally safe and effective, adverse events disproportionately affected those with risk factors. In low-risk eyes, routine corticosteroid use and early follow-up may be unnecessary.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Visual Outcomes, Intraocular Pressure Changes, and Complications Following Nd:YAG (Neodymium-Doped Yttrium Aluminum Garnet) Laser Posterior Capsulotomy for Posterior Capsular Opacification: A Prospective Clinical Study.Cureus · 2026
- Nd:YAG capsulotomy: an update.Medical hypothesis, discovery & innovation ophthalmology journal · 2026
- Nd:YAG Capsulotomy Rates of Three FineVision Trifocal Intraocular Lens Platform Across Different Platforms: Results from a Multicenter Clinical Registry Study.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Risk Factors for Postoperative Hyphema Following Baerveldt Glaucoma Implant Surgery: A Retrospective Cohort StudyJournal of Clinical Medicine · 2026
- Complications and Safety Profile of XEN® Gel Stent in Glaucoma: A Five-Year MAUDE Database Analysis.Current eye research · 2026
- Regional Corneal Densitometry Changes and Endothelial Stability After Cruciate-Pattern Nd:YAG Laser Posterior Capsulotomy: A Retrospective Self-Controlled Study.Diagnostics (Basel, Switzerland) · 2026