Digital Evaluation of the Positional Accuracy of Implant Scan Bodies in All-On-Four Patients Using Digital Approach-A Controlled Clinical Trial.
Y Vijaya Lakshmi, D Sumanth Saketh, N R Dedeepya, P Ramesh, Moulinath Chikati Deepak, T Ankanna
Department of Prosthodontics Crown and Bridge, CKS Theja Institute of Dental Sciences & Research, Tirupathi, Andhra Pradesh, India. · Department of Oral and Maxillofacial Surgery, PES institute of Medical Sciences, Kuppam, Andhra Pradesh, India.
Key points
From the paper's conclusion- The direct-indirect digital impression group displayed the least positional accuracy (402.79 ± 2.6 μm). The accuracy of all three digital impression-making approaches in implant dentistry appears to be clinically acceptable and adequate for all types of implant restorations, especially in All-on-Four treatment modality.
Abstract
AIM: To compare the positional accuracy of the scan body obtained in indirect and direct-indirect digital approaches with that of the direct digital approach. MATERIALS AND METHODS: Twenty implants were placed, each maxilla of four, using All-On-Four concept in five patients. Three impression techniques have been applied to each patient, namely 1) direct digital approach, 2) indirect digital approach, and 3) direct-indirect digital approach. With the use of specialized 3D inspection and metrology software, the difference in scan body position between the groups was calculated. RESULTS: The average total deviation values for the two groups under examination were 343.15 ± 3.4 μm and 402.79 ± 2.6 μm, respectively. For each of the study groups, the deviation measurement between the superimposed scan bodies revealed statistically significant (P = 0.006) differences. A statistically insignificant difference between the compared groups was found by the post hoc analysis (P = 0.006 and 0.014). CONCLUSION: The direct-indirect digital impression group displayed the least positional accuracy (402.79 ± 2.6 μm). The accuracy of all three digital impression-making approaches in implant dentistry appears to be clinically acceptable and adequate for all types of implant restorations, especially in All-on-Four treatment modality.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Influence of splinted vs. non-splinted scan bodies on digital impression accuracy in all-on-four implant rehabilitation: a comparison with conventional open-tray impressions.BMC oral health · 2026
- Implant Position Accuracy of a Dual-Function Bite Holder for Single-Visit Registration of Complete-Arch Implants and Maxillomandibular Relationship: An In Vitro Study.The International journal of oral & maxillofacial implants · 2026
- Accuracy and clinical passive fit of reverse and standard scan body protocols for complete-arch implant-supported digital impressions: An in vitro study.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2026
- The Accuracy of Digital vs Conventional Impression among Patients Receiving Dental Implants: A Systematic Review and Meta Analysis of Clinical Studies : Short title: Digital vs Conventional Impression among Patients Receiving Dental Implants.Galen medical journal · 2026
- Accuracy of Direct Intraoral Versus Reverse Scanning for Abutment-Level Implant Impressions: an In Vitro Study.European journal of dentistry · 2026
- Evaluation of four digital methods in capturing complete-arch implant positions: Direct scanning, splinted scan bodies, three-dimensional-printed scan aids, and intraoral photogrammetry.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2026