Plethysmographic variability index as a measure of fluid responsiveness in patients undergoing major open onco-abdominal surgeries: A prospective observational study.
Malini P Joshi, Shilpushp J Bhosale, Insiya Thanawala, Atul P Kulkarni
Department of Anaesthesia Critical Care and Pain, Advanced Cancer Research and Treatment Centre, Tata Memorial Centre, Homi Bhabha National Institute, Mumbai, Maharashtra, India. · Department of Anaesthesia Critical Care and Pain, Tata Memorial Centre, Homi Bhabha National Institute, Mumbai, Maharashtra, India.
Key points
From the paper's conclusion- We observed that in patients undergoing major open onco-abdominal surgeries, PVI had poor ability to predict fluid responsiveness and could not discriminate between fluid responders and nonresponders.
Abstract
BACKGROUND AND AIMS: Perioperative goal-directed fluid therapy using dynamic measures of fluid responsiveness, such as pulse pressure variation (PPV) or stroke volume variation (SVV), has been shown to reduce perioperative complications. With photoelectric plethysmography, the pulse oximeter sensor noninvasively detects the plethysmographic variability index (PVI), which can be used to assess fluid responsiveness. The aim of the study was to compare the PVI to arterial pressure-based PPV and SVV in predicting fluid responsiveness in patients undergoing major surgeries. MATERIAL AND METHODS: We included 65 adults undergoing elective major open onco-abdominal surgeries and a total of 240 measurements. Intraoperatively, tidal volume was transiently increased from 6 mL/kg to 8 mL/kg (IBW), and PPV, SVV, and PVI were measured. A fluid bolus of 250 mL was given over 10 mins. The PVI, PPV, SVV, cardiac output (CO), cardiac index (CI), and stroke volume (SV) before and immediately after the fluid bolus were recorded. Patients were divided into responders and nonresponders, based on increase in SV of ≥10%. RESULTS: We calculated the area under the ROC curve (AUROC) for all three dynamic parameters. For PVI, the AUC was 0.607 (0.531, 0.683) (P = 0.006), for SVV, the AUC was 0.573 (0.496, 0.65) (P = 0.063), and for PPV, the AUC was 0.605 (0.528, 0.682) (P = 0.007). The sensitivity and specificity for PPV were 86% and 33%, for SVV were 87% and 25%, and for PVI were 86% and 30%, respectively. CONCLUSIONS: We observed that in patients undergoing major open onco-abdominal surgeries, PVI had poor ability to predict fluid responsiveness and could not discriminate between fluid responders and nonresponders.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Variation of perfusion index to evaluate fluid responsiveness during the preload challenge tests: a systematic review and meta-analysis.Annals of intensive care · 2026
- Diagnostic Performance of Pulse Pressure Variation for Predicting Fluid Responsiveness During Spine Surgery in the Prone Position: A Systematic Review and Meta-Analysis.Journal of neurosurgical anesthesiology · 2026
- Association between intraoperative pulse pressure variation and early postoperative nausea and vomiting in major abdominal surgery: A retrospective studyJournal of the Formosan Medical Association · 2026
- Detecting if change in end-tidal carbon dioxide signifies change in cardiac output for the prediction of fluid responsiveness in patients undergoing major abdominal oncosurgery: An observational study.Indian journal of anaesthesia · 2026
- Interchangeability Between Pleth Variability Index and Internal Jugular Vein Variability Index During Laparoscopic Living Donor Nephrectomy: A Prospective Observational Concordance StudymedRxiv · 2026
- Correlation Between Respiratory Blood Flow Velocity Variation and Dynamic Preload Variables During Coronary Artery Bypass Surgery: A Pilot Observational Study.Journal of cardiothoracic and vascular anesthesia · 2026