Correlation Between Respiratory Blood Flow Velocity Variation and Dynamic Preload Variables During Coronary Artery Bypass Surgery: A Pilot Observational Study.
Adrian E Stephan, Christoph Lichtenstern, Markus A Weigand, Cornelius J Busch, Thorsten Brenner, Marcel Hochreiter
Department of Anesthesiology, Heidelberg University Hospital, Heidelberg, Germany. Electronic address: Adrian.Stephan@med.uni-heidelberg.de. · Department of Anesthesiology, Heidelberg University Hospital, Heidelberg, Germany. Electronic address: Christoph.Lichtenstern@med.uni-heidelberg.de.
Key points
From the paper's conclusion- Pressure-derived indices correlated only weakly with echocardiographic respiratory peak velocity variations in patients undergoing CABG. As forward flow did not measurably increase following modified PLR, the physiological significance of these weak correlations remains uncertain.
Abstract
OBJECTIVES: To evaluate correlations between pressure-based dynamic preload indices and echocardiographic flow velocity variations during coronary artery bypass grafting (CABG). DESIGN: Prospective observational pilot study. SETTING: Single university hospital. PARTICIPANTS: Thirty adults undergoing elective CABG. INTERVENTIONS: Modified passive leg raising (PLR) at 3 intraoperative time points. MEASUREMENTS AND MAIN RESULTS: Mean arterial pressure increased after PLR at all 3 time points. In pooled analyses, stroke volume variation decreased from 13% ± 4% to 10% ± 4% and pulse pressure variation decreased from 10% ± 2% to 7% ± 3% (both p < 0.05). Respiratory peak velocity variations in the left ventricular outflow tract and descending aorta did not change significantly. Pulse contour-derived cardiac output also did not change (5.1 ± 1.1 L/min v 5.1 ± 1.1 L/min, p = 0.71). Stroke volume variation and pulse pressure variation correlated strongly (r = 0.720), whereas correlations between pressure- and flow-derived indices were weak (r = 0.147-0.351). CONCLUSIONS: Pressure-derived indices correlated only weakly with echocardiographic respiratory peak velocity variations in patients undergoing CABG. As forward flow did not measurably increase following modified PLR, the physiological significance of these weak correlations remains uncertain.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Plethysmographic variability index as a measure of fluid responsiveness in patients undergoing major open onco-abdominal surgeries: A prospective observational study.Journal of anaesthesiology, clinical pharmacology · 2026
- Brachiocephalic vein distensibility during passive leg raising in healthy adultsScientific Reports · 2026
- Dynamic Arterial Elastance: Physiologic Basis, Current Clinical Evidence, and Future Directions.Anesthesiology · 2026
- Alterations in arterial pressure waveform morphology following volume loading versus vasopressor administration in critically ill patients.Journal of clinical monitoring and computing · 2026
- Variation of perfusion index to evaluate fluid responsiveness during the preload challenge tests: a systematic review and meta-analysis.Annals of intensive care · 2026
- Association between intraoperative pulse pressure variation and early postoperative nausea and vomiting in major abdominal surgery: A retrospective studyJournal of the Formosan Medical Association · 2026