Deep Learning-based Volumetric Modulated Arc Therapy Dose Prediction with Uncertainty Quantification for Left- and Right-sided Breast Cancer: A Single-institution Feasibility Study.
Thanakorn Sukha, Chanon Puttanawarut, Nat Sirirutbunkajorn, Pimolpun Changkaew, Nauljun Stansook, Suphalak Khachonkham
Department of Diagnostic and Therapeutic Radiology, Master of Science Program in Medical Physics, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand. · Department of Clinical Epidemiology and Biostatistics, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.
Key points
From the paper's conclusion- The proposed model supports the feasibility of VMAT dose prediction for both left-and right-sided breast cancer, while the uncertainty maps provide additional confidence information to assist clinical interpretation and decision-making. Uncertainty maps correlated with prediction error and flagged atypical cases. External validation with a larger, multi-institutional dataset is required before clinical implementation can be considered.
Abstract
BACKGROUND: Volumetric-modulated arc therapy (VMAT) enables precise tumor targeting while minimizing dose to organs at risk but requires time-consuming planning with quality variability. Most deep learning (DL) dose prediction studies focus on left-sided breast cancer, with limited exploration of right-sided cases or integrated uncertainty quantification. This study investigates the feasibility of a DL model for VMAT dose prediction in both left-and right-sided breast cancer, incorporating Monte Carlo dropout (MCD)-based uncertainty quantification within a single-institution dataset. METHODS: A total of 68 clinically accepted breast cancer VMAT treatment plans (41 left-sided, 27 right-sided) were collected. A three-dimensional U-Net architecture was implemented. Two models with dropout rates of 0.25 (M0.25) and 0.50 (M0.50) were developed. MCD was applied for uncertainty quantification. Performance was evaluated using mean absolute error (MAE), gamma passing rate (GPR), and isodose Dice similarity coefficients. RESULTS: The overall body MAE was 1.7 ± 0.11 Gy (M0.25) and 1.93 ± 0.11 Gy (M0.50). For the planning target volume (PTV) of 42.56 Gy, MAE was 0.93 ± 0.17 Gy (M0.25) and 0.88 ± 0.15 Gy (M0.50). The heart showed the lowest errors (M0.25: 0.87 ± 0.34 Gy; M0.50: 1.06 ± 0.38 Gy), while contralateral lung exhibited higher uncertainties. GPR at 3%/3 mm reached 85.5% for both models, with no significant difference between left- and right-sided cases. Uncertainty maps correlated with prediction errors (Pearson correlation =0.59) and identified regions with atypical anatomies. CONCLUSIONS: The proposed model supports the feasibility of VMAT dose prediction for both left-and right-sided breast cancer, while the uncertainty maps provide additional confidence information to assist clinical interpretation and decision-making. Uncertainty maps correlated with prediction error and flagged atypical cases. External validation with a larger, multi-institutional dataset is required before clinical implementation can be considered.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- From Predicted Dose to Computationally Verified Plan: An End-to-End Deep Learning and Monte Carlo Pipeline for Automated VMAT Glioblastoma Radiotherapy.Journal of imaging informatics in medicine · 2026
- Deep learning for gamma map prediction in breast IMRT verificationMedical Physics · 2026
- Evaluation of 3D-CRT vs. VMAT for radiotherapy of whole breast with simultaneous integrated boostActa Oncologica · 2026
- Uncertainty estimation for reliable neural network-based radiotherapy dose modelling using Monte Carlo dropout, mean variance estimation and deep ensemble.Physics and imaging in radiation oncology · 2026
- Divergent dose-generating mechanisms for the heart and ipsilateral lung in contemporary breast radiotherapy.Frontiers in oncology · 2026
- Prescription-aware diffusion Transformer for esophageal VMAT dose prediction: a retrospective dual-center validation and target-level analysisBioMedical Engineering OnLine · 2026