Journal of medical physics

FLUKA Monte Carlo-based Evaluation of Linear Energy Transfer Distributions for Monoenergetic Therapeutic Carbon-ion Beams in Water.

Arghya Chattaraj, T Palani Selvam, Vandana Shrivastava

Radiological Physics and Advisory Division, Health, Safety and Environment Group, Bhabha Atomic Research Centre, Mumbai, Maharashtra, India. · Radiological Physics and Advisory Division, Medical Group, Bhabha Atomic Research Centre, Mumbai, Maharashtra, India.

Computational

Key points

From the paper's conclusion
  • Overall, the results provide a comprehensive characterization of physical and radiobiological parameters for monoenergetic carbon-ion beams in the therapeutic energy range, essential for benchmarking LET-based RBE models, improving treatment plan robustness, and optimizing biological dose delivery in carbon-ion radiotherapy.

Abstract

BACKGROUND: This study aims to calculate the distribution of linear energy transfer (LET) and its moments such as fluence-averaged LET (LET f ) and dose-averaged LET (LET d ) as a function of on-axis depth in water for monoenergetic carbon-ion beams with energies ranging from 80 to 480 MeV/u. MATERIALS AND METHODS: Depth-dose profiles, LET distributions, LET f , and LET d are calculated as a function of on-axis depth in a 40 cm × 40 cm × 40 cm unit-density liquid water phantom using the FLUKA Monte Carlo code, fully incorporating the contributions of primary ions and all secondary charged fragments. RESULTS: Results show that both LET f and LET d increase with depth and reach a maximum near the Bragg peak region, followed by a rapid fall-off in the distal region as the fluence of heavy ion fragments decreases. Higher beam energies result in deeper LET peaks and more pronounced fragmentation tails in the depth-dose profiles. In the Bragg peak region, depending on beam energy, the LET f and LET d values are in the range of 11.7-106.4 keV/mm and 210.7-384.6 keV/mm, respectively. CONCLUSION: Overall, the results provide a comprehensive characterization of physical and radiobiological parameters for monoenergetic carbon-ion beams in the therapeutic energy range, essential for benchmarking LET-based RBE models, improving treatment plan robustness, and optimizing biological dose delivery in carbon-ion radiotherapy.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

FLUKA Monte Carlo-based Evaluation of Linear Energy Transfer Distributions for Monoenergetic Therapeutic Carbon-ion Beams in Water — Science Skim