FLUKA Monte Carlo-based Evaluation of Linear Energy Transfer Distributions for Monoenergetic Therapeutic Carbon-ion Beams in Water.
Arghya Chattaraj, T Palani Selvam, Vandana Shrivastava
Radiological Physics and Advisory Division, Health, Safety and Environment Group, Bhabha Atomic Research Centre, Mumbai, Maharashtra, India. · Radiological Physics and Advisory Division, Medical Group, Bhabha Atomic Research Centre, Mumbai, Maharashtra, India.
Key points
From the paper's conclusion- Overall, the results provide a comprehensive characterization of physical and radiobiological parameters for monoenergetic carbon-ion beams in the therapeutic energy range, essential for benchmarking LET-based RBE models, improving treatment plan robustness, and optimizing biological dose delivery in carbon-ion radiotherapy.
Abstract
BACKGROUND: This study aims to calculate the distribution of linear energy transfer (LET) and its moments such as fluence-averaged LET (LET f ) and dose-averaged LET (LET d ) as a function of on-axis depth in water for monoenergetic carbon-ion beams with energies ranging from 80 to 480 MeV/u. MATERIALS AND METHODS: Depth-dose profiles, LET distributions, LET f , and LET d are calculated as a function of on-axis depth in a 40 cm × 40 cm × 40 cm unit-density liquid water phantom using the FLUKA Monte Carlo code, fully incorporating the contributions of primary ions and all secondary charged fragments. RESULTS: Results show that both LET f and LET d increase with depth and reach a maximum near the Bragg peak region, followed by a rapid fall-off in the distal region as the fluence of heavy ion fragments decreases. Higher beam energies result in deeper LET peaks and more pronounced fragmentation tails in the depth-dose profiles. In the Bragg peak region, depending on beam energy, the LET f and LET d values are in the range of 11.7-106.4 keV/mm and 210.7-384.6 keV/mm, respectively. CONCLUSION: Overall, the results provide a comprehensive characterization of physical and radiobiological parameters for monoenergetic carbon-ion beams in the therapeutic energy range, essential for benchmarking LET-based RBE models, improving treatment plan robustness, and optimizing biological dose delivery in carbon-ion radiotherapy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- LETd-dependent RBE conversion between LEM1- and mMKM-based dose systems and characterisation of LETd-dependent uncertainty in carbon ion radiotherapy.Physics in medicine and biology · 2026
- A depth-resolved single-flask 3D clonogenic platform for continuous LET-dependent radiobiological assessment in carbon-ion therapy.Physics in medicine and biology · 2026
- Characterization of animal tissues for Monte Carlo simulations in ion beam therapy.Journal of applied clinical medical physics · 2026
- Clonogenic survival and relative biological effectiveness of pancreatic ductal adenocarcinoma under pristine and spread-out Bragg peak irradiation with protons and carbon ions.bioRxiv · 2026
- Impact of robust optimization and beam configuration on the distribution stability of LET under delivery uncertainties in carbon-ion therapy.Journal of applied clinical medical physics · 2026
- Technical Preparations for the First Carbon-Ion Therapy Facility in the United StatesarXiv · 2026