Marginal and internal adaptation of monolithic computer-aided design and computer-aided manufacturing zirconia crowns and heat-pressed ceramic veneered zirconia crowns: An in vitro study.
Smruti Nanda, Mirna Garhnayak, Abhijita Mohapatra, Sangram Panda, Abhilash Mohapatra, Gopal Krishna Choudhury
Department of Prosthodontics and Crown and Bridge, Institute of Dental Sciences, Siksha 'O' Anusandhan (Deemed to be) University, Bhubaneswar, Odisha, India.
Key points
From the paper's conclusion- Both fabrication workflows produced zirconia crowns with marginal and internal adaptations within clinically acceptable limits. Monolithic CAD/CAM zirconia crowns showed slightly smaller internal discrepancies than heat-pressed ceramic-veneered zirconia crowns; however, the magnitude of this difference is unlikely to affect clinical seating or cementation.
Abstract
AIM: This study aimed to compare the marginal and internal adaptation of monolithic computer-aided design and computer-aided manufacturing (CAD/CAM) zirconia crowns and heat-pressed ceramic-veneered zirconia crowns fabricated using a standardized digital workflow. SETTINGS AND DESIGN: An in vitro laboratory study was conducted using standardized epoxy resin dies and zirconia crowns fabricated by two different laboratory workflows. MATERIALS AND METHODS: Twenty zirconia crowns were fabricated from a single STL dataset with a 50-µm cement space and divided into two groups ( n = 10): monolithic CAD/CAM zirconia (MZ) and bilayer heat-pressed ceramic-on-zirconia (PVZ). All crowns were fabricated on epoxy resin dies replicated from a CAD/CAM-milled stainless-steel master die. After cementation with glass ionomer cement under a controlled seating load of 50 N, the specimens were sectioned buccolingually. Marginal and internal gaps were measured using scanning electron microscopy at eight predetermined sites. STATISTICAL ANALYSIS USED: Data were evaluated for normality using the Shapiro-Wilk test. Intergroup comparisons were performed using the Mann-Whitney U-test, with statistical significance set at P < 0.05. Bonferroni adjustment was applied for exploratory multiple comparisons. RESULTS: For the primary outcome, composite internal adaptation was lower in the monolithic CAD/CAM zirconia crown group than in the heat-pressed ceramic-veneered zirconia crown group (103.07 vs. 111.38 µm; P = 0.019), with a moderate effect size ( r = 0.53). Composite marginal adaptation did not differ significantly between the groups (88.90 vs. 95.73 µm; P = 0.226). CONCLUSION: Both fabrication workflows produced zirconia crowns with marginal and internal adaptations within clinically acceptable limits. Monolithic CAD/CAM zirconia crowns showed slightly smaller internal discrepancies than heat-pressed ceramic-veneered zirconia crowns; however, the magnitude of this difference is unlikely to affect clinical seating or cementation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Manufacturing trueness, internal fit, and planned-to-intraoral spatial concordance of monolithic zirconia crowns fabricated with two commercial ti-base systems: a clinical cross-sectional study.BMC oral health · 2026
- Marginal and Internal Fit of Zirconia Crowns with Varying Yttria Content and Finish Line Configurations: An In Vitro StudyApplied Sciences · 2025
- Influence of repeated milling bur use on the marginal adaptation of monolithic zirconia crowns.The journal of advanced prosthodontics · 2026
- Marginal adaptation of 3D-printed crowns: influence of preparation geometry and digitization workflow.BMC oral health · 2026
- Effect of microscope-assisted preparation refinement on the marginal adaptation of CAD/CAM zirconia crowns prepared by predoctoral dental students.Quintessence international (Berlin, Germany : 1985) · 2026
- From milling to printing: evaluating the applicability of zirconia in restorative dentistry.The journal of advanced prosthodontics · 2026