Marginal adaptation of 3D-printed crowns: influence of preparation geometry and digitization workflow.
Khalid Abdelsalam, Ahmed Attia
Dept of Fixed Prosthodontics, Faculty of Dentistry, Mansoura University, Mansoura, Egypt. · Dept. of Fixed Prosthodontics, Faculty of Dentistry, Mansoura University, El Gomhouria St, Mansoura, Dakahlia Governorate, Egypt. aattia@mans.edu.eg.
Key points
From the paper's conclusion- Within the limitations of this in vitro study, finish line design and workflow type each independently influenced the marginal adaptation of 3D-printed resin matrix ceramic crowns. A heavy chamfer and a direct digital workflow were each associated with smaller marginal gaps.
Abstract
BACKGROUND: This in vitro study evaluated the impact of different workflow and finish line design on the marginal adaptation of 3D printed resin matrix ceramic crowns. METHODS: Forty extracted mandibular molars were randomly allocated into two groups according to finish line design (n = 20); heavy chamfer 0.8 mm (H) and conservative chamfer 0.2 mm (C). Each main group was divided into 2 subgroups (n = 10) according to workflow; direct digital intraoral scanning workflow (D) and semi-digital workflow (S). Crowns were 3D printed from hybrid resin and cemented using adhesive resin cement. Marginal adaptation was evaluated for all groups using a stereomicroscope before cementation and after the combined cementation and artificial aging. Statistical analysis was performed with 3-way ANOVAs and post hoc Tukey test, (P < 0.05). RESULTS: Significant effects were found for finish line design, workflow, and the combined cementation and artificial aging (P < 0.05), with no significant interaction between finish line design and workflow (P = 0.552). Mean marginal gaps (µm) of test groups before cementation and after the combined cementation and aging protocol were: HD, (71.72 ± 4.82), (84.5 ± 2.75); CD, (82.16 ± 3.76), (97.32 ± 3.16); HS, (92.51 ± 3.64), (111.8 ± 3.37); and CS, (106.1 ± 3.57), (123.4 ± 2.58). All groups showed significant increases thereafter (P < 0.05). Heavy chamfer finish line and direct digital workflow each yielded significantly smaller marginal gap than conservative chamfer and semi-digital workflow at both time points (P < 0.05). CONCLUSIONS: Within the limitations of this in vitro study, finish line design and workflow type each independently influenced the marginal adaptation of 3D-printed resin matrix ceramic crowns. A heavy chamfer and a direct digital workflow were each associated with smaller marginal gaps.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fracture Resistance and Marginal Adaptation of 3D-Printed Versus Milled Resin-Based Permanent Crowns: A Systematic Review and Meta-Analysis.Journal of esthetic and restorative dentistry : official publication of the American Academy of Esthetic Dentistry ... [et al.] · 2026
- Three-Dimensional Evaluation of Marginal Gap in Prefabricated Zirconia and 3D-Printed Pediatric Crowns.Materials (Basel, Switzerland) · 2026
- Marginal and Internal Adaptation of Crowns Fabricated on Models From Digital and Conventional Impressions: An In Vitro Study.Journal of esthetic and restorative dentistry : official publication of the American Academy of Esthetic Dentistry ... [et al.] · 2026
- Micro-Computed Tomography Evaluation of the Marginal and Internal Fit of Ceramic-Filled Resin Crowns Fabricated by Subtractive and Additive Manufacturing.Australian dental journal · 2026
- Comparison of Implant-Supported Permanent Crowns Produced wıth Different 3D Printed Resins in Terms of Productıon Accuracy, Marginal Fit and Internal Fit: A Comparative in Vitro StudyThe International Journal of Prosthodontics · 2026
- Accuracy and Fit of Three-Unit Dental Restorations Fabricated from 3D-Printed Resins and CAD/CAM Milling Materials: A Micro-CT StudyBioengineering · 2026