Design of a novel dental bone mapping caliper for chairside ridge assessment: A technical note.
Brajendra Singh Tomar, Shubhra Singh
Department of Prosthodontics Crown and Bridge and Implantology, Rishiraj College of Dental Sciences and Research Centre, Bhopal, Madhya Pradesh, India. · Department of Periodontology, Rishiraj College of Dental Sciences and Research Centre, Bhopal, Madhya Pradesh, India.
Key points
From the paper's conclusion- The novel dental bone mapping caliper represents a practical chairside tool for ridge assessment and may improve the standardization of transgingival bone mapping procedures. Further clinical investigations are necessary to establish its effectiveness relative to existing methods.
Abstract
BACKGROUND: Accurate assessment of alveolar ridge width is essential for implant treatment planning. Although cone-beam computed tomography provides detailed three-dimensional information, chairside ridge-mapping techniques remain valuable because of their simplicity, accessibility, and cost-effectiveness. OBJECTIVE: The objective of this study was to describe the design, clinical application, and potential advantages of a novel dental bone mapping caliper for transgingival ridge assessment. TECHNICAL DESCRIPTION: The proposed instrument incorporates a blunt external reference arm, a controlled transgingival probing tip, a calibrated sliding measurement scale, and an ergonomically designed handle within a single device. The instrument enables direct chairside measurement of alveolar ridge width while improving stabilization and measurement standardization. CLINICAL APPLICATION: The caliper is used during transgingival ridge mapping by positioning the blunt arm against the mucosal surface and advancing the probing tip until cortical bone contact is achieved. Measurements are recorded directly from the calibrated scale. DISCUSSION: Compared with conventional ridge-mapping methods, the proposed design offers improved operator control, direct measurement recording, enhanced stability, and simplified clinical workflow. However, clinical validation studies are required to determine its accuracy, reproducibility, and patient acceptance. CONCLUSION: The novel dental bone mapping caliper represents a practical chairside tool for ridge assessment and may improve the standardization of transgingival bone mapping procedures. Further clinical investigations are necessary to establish its effectiveness relative to existing methods.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Agreement Between Cone Beam Computed Tomography, Bone Sounding, Pulse-Echo Ultrasound, and Caliper Measurements for Gingival Thickness Assessment: A Method-Comparison Study.Dentistry journal · 2026
- In vivo evaluation comparison of noncalibrated implant scan body systems positioned following the arch shape or toward the center of the arch.The Journal of prosthetic dentistry · 2026
- Within-Device Exposure-Setting and Voxel-Size Changes in CBCT Alveolar Bone Measurement for Implant Planning: A Systematic Review.Tomography (Ann Arbor, Mich.) · 2026
- Interimplant distance and angulation measurement from CAD-generated multiunit abutment interfaces: A scan body-independent technique.The Journal of prosthetic dentistry · 2026
- Implant Position Accuracy of a Dual-Function Bite Holder for Single-Visit Registration of Complete-Arch Implants and Maxillomandibular Relationship: An In Vitro Study.The International journal of oral & maxillofacial implants · 2026
- Root Canal Taper and the Accuracy of Intraoral Scanners for Post Space Measurement: An In Vitro Study.European journal of dentistry · 2026