Precision in endodontics: Comparison of four different working length determination methods with three irrigation solutions - An in vivo study.
Sarvepalli Venkata Satish, M S Nishanth, Suresh Kumar Kovvuru, Basavana Gouda, Ashwini M Patil
Department of Conservative Dentistry and Endodontics, Navodaya Dental College and Hospital, Raichur, Karnataka, India.
Key points
From the paper's conclusion- Both standalone and IALs provide clinically accurate, radiation-free WL determination comparable to CBCT across all three irrigants. IALs offer additional procedural efficiency and are suitable for routine clinical practice.
Abstract
CONTEXT: Accurate working length determination is essential for endodontic success, yet the optimal method among radiographic, electronic, and imaging-based techniques remains debated. AIMS: The aim of the study was to compare the accuracy of working length (WL) determination using an electronic apex locator (EAL), an integrated apex locator (IAL), cone beam computed tomography (CBCT), and conventional periapical radiography and to evaluate the influence of three root canal irrigants - three percent sodium hypochlorite (NaOCl), Twinkleen, and saline - on measurement accuracy. MATERIALS AND METHODS: A prospective in vivo randomized comparative study was conducted on forty-five single-rooted permanent teeth requiring primary root canal treatment. Preoperative CBCT (Carestream CS9300) served as the reference standard. WL was additionally determined by conventional periapical radiography (Carestream RVG 5200), the Root ZX Mini EAL (J Morita, Japan), and the CanalPro CL2i IAL (COLTENE-Whaledent, USA). Participants were randomly allocated to three groups (n = fifteen each) by irrigant: Group I - three percent NaOCl; Group II-Twinkleen; Group III-Saline. STATISTICAL ANALYSIS USED: One-way analysis of variance and Tukey's post hoc test (alpha = 0.05) were used for statistical analysis. RESULTS: Both the Root ZX Mini and CanalPro CL2i produced WL measurements closely approximating CBCT values across all irrigants, with mean differences ≤0.23 mm and interdevice differences ≤0.10 mm (P > 0.05). Conventional radiographs showed the greatest deviation from CBCT (mean difference approximately 0.64 mm). No statistically significant difference was found among any measurement pair. Saline caused the least variability, followed by Twinkleen and three percent NaOCl. CONCLUSIONS: Both standalone and IALs provide clinically accurate, radiation-free WL determination comparable to CBCT across all three irrigants. IALs offer additional procedural efficiency and are suitable for routine clinical practice.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Accuracy of working length determination using endodontic motors with integrated electronic apex locators: an in vitro study.Frontiers in oral health · 2026
- The effect of root canal preparation and intracanal medicaments on the accuracy of electronic apex locators.Odontology · 2026
- Evaluation of postoperative pain associated with different working length determination methods: a randomised clinical study.BMC oral health · 2026
- Comparative Evaluation of Depth of Irrigant Penetration Using Different Irrigation Systems: An In Vivo Study.Cureus · 2026
- Apical debridement of necrotic oval root canals with irrigation protocols activated by passive ultrasonic irrigation, R-SWEEPS, or OdneClean: an ex vivo histological studyFrontiers in Dental Medicine · 2026
- Effects of Sodium Hypochlorite Concentration and Final Irrigation Protocol on Residual Filling Material in Retreated Oval Root Canals Obturated with a Calcium Silicate-Based Sealer: A Scanning Electron Microscopy Study.Medicina (Kaunas, Lithuania) · 2026