Accuracy of working length determination using endodontic motors with integrated electronic apex locators: an in vitro study.
Huynh-Anh Bui, Minh-Anh Bui, Thi-Thuy-Trang Huynh, Hoang-Lan-Anh Le, Phuong-Doan Phan, Nguyen-Tra-Mi Le, Thuan-Loc Tran, Thi-Bich-Van Tran,
Faculty of Dentistry, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam. · Faculty of Operative Dentistry and Endodontics, National Hospital of Odonto-Stomatology, Ho Chi Minh City, Vietnam.
Key points
From the paper's conclusion- The data were analysed using Bland-Altman agreement analysis (mean bias and 95% limits of agreement) in MedCalc, with between-device comparison performed using a test appropriate for the independent two-group design; significance was set at 0.05.
Abstract
The aim of the present study was to evaluate the accuracy of endodontic motors with an integrated electronic apex locator (EAL) for determining endodontic working length under in vitro conditions. A total of twenty-six extracted human mandibular single-canal premolars were included and scanned via cone-beam computed tomography (CBCT), three-dimensionally reconstructed, and then allocated equally into two device groups (n = 13 each). The teeth were accessed and a glide path was prepared with a manual K-file before the canals were prepared with a continuous single-file system (One Curve, Micro-Mega, Besançon, France) driven by one of two integrated endodontic motor/EAL systems (Connect Drive, VDW; and E-Connect S, Eighteeth) until the auto-apical-reverse ("apex") signal was displayed. The teeth were scanned by CBCT a second time after preparation, and 3D reconstruction was performed to determine the post-preparation endpoint. Subtraction of the pre- and post-preparation images was used to evaluate the accuracy of the working length relative to the directly measured actual length. The data were analysed using Bland-Altman agreement analysis (mean bias and 95% limits of agreement) in MedCalc, with between-device comparison performed using a test appropriate for the independent two-group design; significance was set at 0.05. There was no significant difference in working length between the two integrated systems. Under the present in vitro conditions, neither integrated motor/EAL system produced measurements identical to the reference length, although the deviations were small: the mean bias of the auto-apical-reverse endpoints relative to the actual length ranged from approximately 0.13 to 0.26 mm, remaining within the ±0.5 mm clinical tolerance, and the largest single deviation recorded was 0.79 mm short of the major apical foramen. The working length should therefore be confirmed using complementary methods rather than relying solely on the auto-reverse endpoint.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Micro-CT evaluation of canal shaping extent with apex locator-integrated endodontic motors: An in vitro study.PloS one · 2026
- The effect of root canal preparation and intracanal medicaments on the accuracy of electronic apex locators.Odontology · 2026
- Precision in endodontics: Comparison of four different working length determination methods with three irrigation solutions - An in vivo study.Journal of conservative dentistry and endodontics · 2026
- Comparing the accuracy and active drilling time of robot-assisted and dynamic navigation systems in access cavity preparation: an in vitro study.BMC oral health · 2026
- Can Contemporary NiTi Systems Reach the Full Working Length Without Prior Glide Path Preparation? A Scoping Review.Australian endodontic journal : the journal of the Australian Society of Endodontology Inc · 2026
- An Integrated Instrument for Endodontic Access Cavity Preparation and Root Canal Preparation with Full Pneumatic DriveSAE technical papers on CD-ROM/SAE technical paper series · 2026