Autologous rotational partial thickness scleral flap - A salvage technique for late leaking blebs with scleral fistula.
Dewang Angmo, Subodh Lakra, Tanuj Dada
Department of Ophthalmology, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India.
Key points
From the paper's conclusion- This manuscript delineates a modified autologous rotational partial-thickness scleral flap technique employed as a salvage procedure in managing late, leaking, thin cystic blebs with underlying scleral fistulae.
Abstract
Success rates for trabeculectomy have notably advanced with the adjunctive use of antifibrotic agents, particularly mitomycin C. Despite this, the increased prevalence of thin, cystic blebs and late-onset bleb leaks, particularly those complicated by scleral fistula formation, represents a visually threatening sequela. This manuscript delineates a modified autologous rotational partial-thickness scleral flap technique employed as a salvage procedure in managing late, leaking, thin cystic blebs with underlying scleral fistulae. In two patients managed with this technique, we observed re-establishment of an anatomically stable, moderately vascularized bleb, and maintenance of intraocular pressure within target range over 18-24 months. The procedure utilizes trypan blue-assisted peeling of the epithelium and a rotational, partial-thickness scleral flap, with conjunctival advancement, thereby achieving tectonic support and functional preservation of filtration.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical outcomes of repositioning subluxated in-the-bag intraocular lenses using the flanged belt-loop technique with 6-0 polypropyleneJournal of Cataract & Refractive Surgery · 2025
- Novel surgical approach to correct late-hypotony in PreserFlo MicroShunt.The British journal of ophthalmology · 2026
- A Novel Modification of the Yamane Intrascleral Haptic Fixation Technique with Scleral Groove-Flap Coverage: A Case Series Study.International medical case reports journal · 2026
- Multilayer fascia lata reconstruction for recurrent ventral cervical cerebrospinal fluid leak following anterior cervical surgery: A technical case report.Surgical neurology international · 2026
- Late-onset filtering bleb complications: A review.Survey of ophthalmology · 2026
- Management of bleb leak in filtration surgeries and novel use of lyophilized amniotic membrane - A multi-center case-series.Journal francais d'ophtalmologie · 2026