Clinical outcomes of repositioning subluxated in-the-bag intraocular lenses using the flanged belt-loop technique with 6-0 polypropylene
Gülay Yalçınkaya Çakır, Ahmet Kırgız, Seda Liman Uzun, Nilay KANDEMİR BEŞEK, Sibel Ahmet
Izmir University
Key points
From the paper's conclusion- The flanged belt-loop technique is a safe and effective option for repositioning subluxated in-the-bag IOLs, avoiding the need for IOL explantation.
Abstract
PURPOSE: To evaluate the clinical outcomes of scleral fixation using the flanged belt-loop technique in patients with in-the-bag intraocular lens (IOL) subluxation after cataract surgery. SETTING: Beyoglu Eye Training and Research Hospital, Turkey. DESIGN: Retrospective. METHODS: 23 eyes of 23 patients who underwent scleral fixation of subluxated in-the-bag IOLs using the flanged belt-loop technique, with a minimum follow-up of 6 months, were included. All surgeries were performed by a single experienced surgeon. The procedure involved transscleral fixation of the existing IOL using 6-0 polypropylene sutures with flanged ends, without conjunctival dissection or use of scleral flaps. Preoperative and postoperative data were collected, including corrected distance visual acuity (CDVA), intraocular pressure (IOP), corneal endothelial cell density (ECD), and central corneal thickness (CCT). RESULTS: The mean postoperative CDVA improved significantly ( P = .001). IOLs remained well-centered in 91.3% of eyes. Mild, asymptomatic decentration occurred in 2 eyes. There were no significant changes in IOP, ECD, or CCT ( P > .05). No major intraoperative or postoperative complications were reported. The surgical time was relatively short, and the technique caused minimal trauma to anterior segment structures. Bilateral haptic fixation was associated with better centration, especially after the initial learning curve. CONCLUSIONS: The flanged belt-loop technique is a safe and effective option for repositioning subluxated in-the-bag IOLs, avoiding the need for IOL explantation. Its minimally invasive nature, short operative time, and stable outcomes make it a favorable alternative. Larger studies with longer follow-up are necessary to validate these findings and compare efficacy with other fixation methods.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Novel Intraocular Lens and Capsular Bag Complex Suspension Technique for Repositioning Late In-the-Bag Intraocular Lens Dislocation.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Flanged Polypropylene Suture for Preset One-Piece Acrylic Intraocular Lens Fixation with Pre-Threaded Needle Technique: Surgical Technique and Short-Term Clinical Outcomes.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Haptic-Extended Flange Intrascleral Fixation for Single-Piece Acrylic Intraocular Lenses.Journal of clinical medicine · 2026
- Scleral suture fixation of a foldable intraocular lens without a scleral flap or groove.Romanian journal of ophthalmology · 2026
- Extraocularly Manipulated Flangeless Intrascleral Haptic Fixation of Intraocular Lens Using Zigzag Needles.Cureus · 2026
- Repositioning dislocated rigid C- loop intraocular lens using double rectangle prolene 10-0 sutures: A novel technique.European journal of ophthalmology · 2026