Positive predictive value of tactile tracheal tube cuff ballotability above the suprasternal notch in detecting the correct positioning of the tracheal tube - A diagnostic accuracy study.
Viswanath Selvam, Venkata Ganesh, Sameer Vyas, Lakshmi Narayana Yaddanapudi, Hemant Bhagat
Department of Anaesthesia and Intensive Care, Postgraduate Institute of Medical Education and Research, Chandigarh, India. · Department of Radiodiagnosis and Imaging, Postgraduate Institute of Medical Education and Research, Chandigarh, India.
Key points
From the paper's conclusion- In this study of non-obese adults under general anaesthesia, suprasternal tactile cuff ballotability had high sensitivity (98.1%) but moderate specificity (60.0%) for identifying the radiographic cuff position at or above T2 vertebral body, with excellent interobserver agreement (κ = 0.77).
Abstract
BACKGROUND AND AIMS: Most endotracheal tube (ETT) depth assessment methods require extra equipment or expertise. Suprasternal tactile cuff ballotability is a bedside technique; however, its performance against a radiographic standard is not well characterised. This study assessed the accuracy of identifying an ETT cuff position above the lower border of the second thoracic vertebral body (T2LB) on fluoroscopy, interobserver agreement, and the relationship with tip-to-carina distance. METHODS: This prospective observational study enroled adults undergoing neuroradiological procedures under general anaesthesia. After intubation, cuff ballotability was assessed by compressing the pilot balloon while palpating the trachea cephalad to the suprasternal notch. Ballotability, ETT marking at the mouth angle, and tip-to-carina distance were recorded. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) with 95% confidence intervals (CIs) were calculated. Interobserver agreement used Fleiss' Kappa (k). RESULTS: Of 85 screened patients, 76 were recruited [mean age 43.58 (13.47) years], and 72 underwent analysis. The correct placement prevalence was 72%. The sensitivity was 98.08% (94.90%-100%), specificity 60.00% (46.68%-71.32%), PPV 86.44% (78.53%-94.35%), and NPV 92.31% (86.15%-98.46%). The interobserver agreement was excellent (κ = 0.77, P < 0.001). The tip-to-carina distance was greater with ballotability (mean difference 17.9 mm; P = 0.001). CONCLUSION: In this study of non-obese adults under general anaesthesia, suprasternal tactile cuff ballotability had high sensitivity (98.1%) but moderate specificity (60.0%) for identifying the radiographic cuff position at or above T2 vertebral body, with excellent interobserver agreement (κ = 0.77).
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Protocol and Statistical Analysis Plan for the Waveform Capnography versus Colorimetric Carbon Dioxide Detection During Tracheal Intubation of Critically Ill Adults (WAVE) StudymedRxiv · 2026
- Front-of-neck point-of-care ultrasound versus capnography for detection of tracheal tube position during cardiopulmonary resuscitation: a randomized simulation-based trialInternational Journal of Emergency Medicine · 2026
- Point-of-care ultrasound of the upper airway for direct confirmation of correct endotracheal tube placement in paediatric patients: analysis of 110 cases.International journal of pediatric otorhinolaryngology · 2026
- Comparing Subglottic Ultrasound and Distal Phalanx Width for Pediatric Endotracheal Tube Sizing in a Predominantly School-Aged Pediatric Cohort: A Prospective Study.Paediatric anaesthesia · 2026
- Diagnostic accuracy of point-of-care ultrasound and radiography for triage of laryngotracheal stenosis in resource-limited settings: a prospective study protocol.BMJ open · 2026
- Comparison of Two Modified Nasal-Tragus Length Methods for Estimating Orotracheal Tube Depth in Thai Neonates: A Randomized Controlled Trial.Neonatology · 2026