International journal of pediatric otorhinolaryngology

Point-of-care ultrasound of the upper airway for direct confirmation of correct endotracheal tube placement in paediatric patients: analysis of 110 cases.

Mariagrazia Cicala, Alessio Pacini, Maria Vittoria Pesce, Giacomo Monaco, Leonardo Emberti-Gialloreti, Costantino Eugenio Buonopane, Debora Felicetti

Department of Biomedicine and Prevention, University of Rome Tor Vergata, Italy. Electronic address: mariagraziacicala@hotmail.it. · Emergency Department, Critical Care and Trauma Areas, Policlinico Umberto I University Hospital, Italy.

Observational · n=110

Key points

From the paper's conclusion
  • Upper-airway point-of-care ultrasound appears feasible as an adjunct for confirming paediatric orotracheal intubation. Static signs were identified more consistently than some dynamic signs. Further studies including sufficient esophageal or misplaced intubations are needed to establish specificity and overall diagnostic accuracy.

Abstract

BACKGROUND: Point-of-care ultrasound of the upper airway can rapidly confirm the anatomical position of the endotracheal tube without the need for preliminary ventilation. However, evidence on specific sonographic signs in children remains limited. METHODS: This prospective, single-centre, observational study included children undergoing elective ENT surgery under general anesthesia. The study assessed four predefined ultrasound signs of the upper airway: the snowstorm sign, the bullet sign, the tracheal dilatation sign, and the absence of the double-track sign. Bilateral lung sliding was also evaluated. Correct intubation was defined as quantitative capnography combined with bilateral chest auscultation. The sensitivity, positive and negative predictive values, and 95% confidence intervals were estimated for the individual signs, combinations of signs, and a cumulative ultrasound score. RESULTS: A total of 104 children were included in the study, of whom 103 had correct tracheal intubation. The sensitivity was found to be 81.6% for the snowstorm sign, 75.7% for the tracheal dilatation sign, 53.4% for the bullet sign and 100% for both the absence of the double-track sign and bilateral lung sliding. At least one positive dynamic sign showed 85.4% sensitivity, while at least one positive static sign or a cumulative score of at least one both achieved 100% sensitivity. The positive predictive values were consistently high, reflecting the absence of false positives in a cohort with almost exclusively successful intubations. CONCLUSIONS: Upper-airway point-of-care ultrasound appears feasible as an adjunct for confirming paediatric orotracheal intubation. Static signs were identified more consistently than some dynamic signs. Further studies including sufficient esophageal or misplaced intubations are needed to establish specificity and overall diagnostic accuracy.