Anterior Stromal Melt Following Implantation of a Large Size Corneal Allogenic Intrastromal Ring Segment (CAIRS).
Karen E Asfar, Soosan Jacob, Jad F Assaf, Farhad Hafezi, Shady T Awwad
Department of Ophthalmology, Corneal and Refractive Surgery Division, American University of Beirut Medical Center, Beirut, Lebanon. · Dr. Agarwal's Eye Hospital, Chennai, India.
Key points
From the paper's conclusion- The large segment size placed superficially may have contributed to localized biomechanical stress, particularly in eyes with advanced keratoconus. Safe thresholds for segment/tunnel sizes, depth, and location warrant further studies.
Abstract
PURPOSE: To report delayed anterior stromal melt following corneal allogenic intrastromal ring segment (CAIRS) implantation in a patient without known systemic or ocular risk factors. METHODS: A 62-year-old man with advanced bilateral keratoconus underwent femtosecond laser-assisted CAIRS implantation at 260 µm depth (900 µm tunnel width). Three months postoperatively, CDVA improved from 20/150- and 20/400 to 20/80 bilaterally and Kmax improved from 59.67 and 67.56 diopters (D) to 54.39 and 64.72 D in the right and left eyes, respectively. Optical coherence tomography (OCT) measured the segment at 624 µm in the right eye. RESULTS: Ten months postoperatively, the right eye demonstrated focal epithelial thinning with fluorescein staining and melt localized over the inferotemporal segment; overlying stromal thickness decreased from 133 µm (week 1) to 7 µm on OCT. The left eye remained unaffected. Topical loteprednol, lubrication, and systemic doxycycline were initiated. Nineteen months postoperatively, OCT and topography demonstrated stromal stability. Despite astigmatic regression, CDVA remained better than baseline, and the CAIRS was retained. CONCLUSIONS: The large segment size placed superficially may have contributed to localized biomechanical stress, particularly in eyes with advanced keratoconus. Safe thresholds for segment/tunnel sizes, depth, and location warrant further studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Visual, Tomographic, and Biomechanical Outcomes of CAIRS with Accelerated Cross-Linking in Moderate to Advanced Keratoconus: A 6-Month Retrospective Case Series.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Repeatability and Reliability of Corneal Tomography in Keratoconus Patients with Corneal Allogenic Intrastromal Ring Segments.Beyoglu eye journal · 2026
- Microbial Keratitis After Corneal Allograft Intrastromal Ring Segment ImplantationCornea Open · 2026
- Extracorporeal Optimization of Corneal Allogenic Intrastromal Ring Segments (ECO-CAIRS) Using Ultra-high-Fluence Corneal Cross-linkingJournal of Refractive Surgery · 2025
- Clinical and Tomographic Outcomes of Long Arc-Length Intrastromal Corneal Ring Segment Implantation in Central Keratoconus.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Corneal Allogeneic Intrastromal Ring Segments for keratoconus – recent evidence and the move to customized and custom shaped CAIRSCurrent Opinion in Ophthalmology · 2026