Clinical utility of endorectal balloons in prostate cancer external beam radiotherapy: a systematic review and meta-analysis.
You Lim Kim, Jeong Il Yu, Jae Kyung Suh
Division for Healthcare Technology Assessment Research, National Evidence-based Healthcare Collaborating Agency, Seoul, Republic of Korea. · Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea. jeongil.yu@samsung.com.
Key points
From the paper's conclusion- ERB appears to be a relatively safe and clinically useful adjunct for enhancing treatment precision in prostate cancer radiotherapy. By stabilizing prostate motion and reducing radiation exposure to the rectum and anal wall, ERB optimizes the therapeutic ratio.
Abstract
PURPOSE: This study aimed to systematically evaluate the clinical utility of endorectal balloons (ERB) for motion management and organ-at-risk sparing in prostate cancer patients receiving external beam radiotherapy (EBRT) or stereotactic body radiotherapy (SBRT). MATERIALS AND METHODS: A systematic search was conducted in Ovid MEDLINE, Embase, the Cochrane Library, and Korean databases through May 8, 2024. Primary outcomes included safety, toxicity, prostate motion, and dosimetric parameters. The risk of bias was assessed using the Risk of Bias Assessment tool for Non-randomized Studies 2.0 tools. Meta-analysis was conducted using Review Manager 5.3. RESULTS: Twenty-seven studies (3 prospective cohort studies, 24 retrospective studies) were included, covering 22 EBRT and 5 SBRT cohorts. Reported adverse events were mild and transient. One prospective study demonstrated a significant reduction in grade 1 late rectal toxicity (p = 0.003). ERB use significantly stabilized the prostate, reducing both intra- and interfractional motion, particularly minimizing displacements >5 mm. Meta-analysis revealed that ERB significantly lowered the mean radiation dose to the rectum (mean difference [MD], -3.40 Gy; 95% confidence interval [CI], -6.70 to -0.10) and anal wall (MD, -6.06 Gy; 95% CI, -9.78 to -2.35) in EBRT. Similarly, in SBRT, ERB was associated with reduced rectal wall dose (MD, -2.63 Gy; 95% CI, -4.49 to -0.77). CONCLUSION: ERB appears to be a relatively safe and clinically useful adjunct for enhancing treatment precision in prostate cancer radiotherapy. By stabilizing prostate motion and reducing radiation exposure to the rectum and anal wall, ERB optimizes the therapeutic ratio.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biological equivalent dose assessment of hydrogel spacer dosimetric impact in prostate cancer EBRTJournal of Applied Clinical Medical Physics · 2026
- Preliminary evaluation of ProSpare®, a rectal obturator for prostate bed radiotherapy within the randomised multicentre POPS trial (NCT02978014).Frontiers in oncology · 2026
- Endorectal balloon facilitated dose-escalation salvage radiation therapy without compromising rectal dose constraints for a solitary macroscopic recurrence in prostate bed after prostatectomy.Medical dosimetry : official journal of the American Association of Medical Dosimetrists · 2026
- Safety and early outcomes of external beam radiation therapy with low dose brachytherapy boost in patients with prostate cancer: A single institution experience.Brachytherapy · 2026
- Image-guided high-dose-rate brachytherapy after short-course external beam radiotherapy for elderly/frail rectal cancer patients.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2026
- Prospective Evaluation of Three-Fraction SBRT with 4D Transperineal Ultrasound Intrafraction Motion Monitoring for Localized Prostate Cancer.Cancers · 2026