Biological equivalent dose assessment of hydrogel spacer dosimetric impact in prostate cancer EBRT
Honglai Zhang, Jenghwa Chang, Jeffrey Antone, Louis Potters, Yijian Cao
Key points
From the paper's conclusion- Conclusion Hydrogel spacer insertion consistently and significantly improved rectal dose sparing for prostate cancer patients undergoing EBRT across all investigated fractionation schemes.
Abstract
Background The dosimetric impact of hydrogel spacer in prostate cancer radiation therapy for reducing rectal radiation dose and mitigating toxicity has been well documented in the literature. Purpose This study aimed to evaluate rectal dose sparing with hydrogel spacer placement in prostate cancer patients treated with External Beam Radiation Therapy (EBRT) across different fractionation schemes. Methods A retrospective analysis was conducted on 254 patients: 179 patients received a hydrogel spacer, while 75 did not. Patients underwent EBRT with one of the following regimens: conventional fractionation (81 Gy in 45 fractions), hypofractionation (70 Gy in 28 fractions), or Stereotactic Body Radiotherapy (SBRT; 40 Gy in 5 fractions). To enable comparison across these schemes, volumetric doses for rectal wall (0.1, 0.5, 1, 2, 5, and 10 cm 3 ) were calculated as Biological Effective Doses (BED) and subsequently converted to their Biological Equivalent Doses in 2 Gy fractions (EQD2). Results Hydrogel spacer insertion significantly improved rectal dose sparing across all evaluated fractionation schemes ( p < 0.01). For conventional fractionation group with spacer insertion, average rectal wall EQD2 was reduced by 13.0% to 51.4% across volumes ranging from 0.1 to 10 cm 3 . EQD2_max decreased by 7.4%, and EQD2_mean by 18.2%. In hypofractionation group, spacer placement led to rectal wall EQD2 reductions of 11.1% to 43.0% across the same volumes. EQD2_max decreased by 4.3%, and EQD2_mean by 21.5%. In SBRT, spacer insertion resulted in rectal wall EQD2 decreases of 17.7% to 40.8% for those volumes. Rectal wall EQD2_max and EQD2_mean were reduced by 6.3% and 22.5%, respectively. All reported reductions were statistically significant ( p < 0.01). Conclusion Hydrogel spacer insertion consistently and significantly improved rectal dose sparing for prostate cancer patients undergoing EBRT across all investigated fractionation schemes. Notably, more substantial dose reductions were observed in larger rectal wall volumes, indicating a greater protective benefit with increased tissue involvement.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Assessment of Hydrogel Rectal Spacer Effectiveness and Safety in Individuals With Prostate Cancer Undergoing Radiotherapy - A Large Claims Database Study.The Prostate · 2026
- Case Report: Outpatient management of rectal infiltration by iodinated polyethylene glycol hydrogel and stabilized hyaluronic acid spacers in patients with prostate cancer.Frontiers in oncology · 2026
- Clinical utility of endorectal balloons in prostate cancer external beam radiotherapy: a systematic review and meta-analysis.Radiation oncology journal · 2026
- Dosimetry, Toxicity and Stability Associated With a Hyaluronic Acid-Based Prostate-Rectal Spacing Device During Prostate Radiation Therapy: A Retrospective Comparative Analysis.Journal of medical radiation sciences · 2026
- Interfractional Monitoring of Spacer Hydrogel Morphology in Patients With Prostate Cancer Receiving SBRT Treatment.Practical radiation oncology · 2026
- Pulmonary embolism following spacer hydrogel intravasation: A case report of a rare rectal spacer complication in prostate cancer radiotherapy.Central European journal of urology · 2026