Working Channel Position and Flexible Ureteroscope Performance: An In Vitro Comparative Study.
Dyandra Parikesit, Quoc Anh Nguyen Van, Christine Joy Castillo, Steffi Kar Kei Yuen, Majed Alharthi, Jose Carlo R Elises, Sung Yong Cho
Urology Medical Staff Group, Universitas Indonesia Hospital, Universitas Indonesia. · Department of Urology, Hue Central Hospital.
Key points
From the paper's conclusion- The findings identify working channel configuration as a potentially relevant design factor that requires controlled and clinical validation.
Abstract
Flexible ureteroscopy (fURS) is a mainstay of treatment for intrarenal stones, and the position of the working channel determines the direction from which a basket or other instrument enters the endoscopic field. Working channel position (WCP) has nevertheless received little systematic evaluation as a design variable, and ureteroscopes with a 6 o'clock channel have not previously been compared with conventional 3 and 9 o'clock designs. It was hypothesized that ureteroscopes with different working channel configurations would show measurable, task-specific differences in navigation, stone interaction, and operator ergonomics under standardized conditions. Four digital ureteroscopes representing 3 o'clock (Flex-Xc, LithoVue), 6 o'clock (URUS), and 9 o'clock (Lscope) configurations were evaluated in a life-size three-dimensional printed model of the right and left collecting systems reconstructed from a de-identified patient computed tomography dataset. A single experienced endourologist performed timed navigation to each color-coded calyx, quantification of calyceal visualization using predefined intracalyceal surface dots, ureteroscope-tip contact with artificial stones, basket relocation of a stone from the lower-posterior to the upper-posterior calyx, and assessment of wrist range of motion and self-reported fatigue. Differences in navigation time, calyceal visualization, relocation time, wrist range of motion, and operator-reported comfort were observed among ureteroscopes with different working channel configurations, and these differences varied by kidney side and calyx location. Flex-Xc showed the shortest navigation times in selected calyces, URUS showed more consistent stone relocation between the two kidneys together with favorable operator-reported comfort, and Lscope required longer completion times in the right kidney. Because the devices also differed in diameter, deflection, weight, and single-use versus reusable design, these differences cannot be attributed to WCP alone. The findings identify working channel configuration as a potentially relevant design factor that requires controlled and clinical validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative performance of single-use flexible ureteroscopes with and without direct in-scope suction: a retrospective analysis.Journal of medicine and life · 2026
- Comparison of Two Fluid-Management Platforms for Flexible Ureteroscopy in Renal Stone Treatment: Pressure-Feedback Irrigation and Aspiration Versus a Suction Access Sheath Without Pressure FeedbackSurgeries · 2026
- Robotic Flexible Ureteroscopy: A Step-by-Step Guide to the ILY® Platform.International braz j urol : official journal of the Brazilian Society of Urology · 2026
- First European experience with LithoVue™ Elite: Multicentre end-user experience and feedback.Central European journal of urology · 2026
- Optimizing flexible and navigable ureteral access sheaths (FANS) manoeuvrability: the impact of sheath size, working channel occupancy and deflection technique - an EAU endourology in vitro analysis.BMC urology · 2026
- Steerable versus Conventional flexible and navigable suction ureteral access sheath (FANS) flexible Ureteroscopy for Lower Pole stones Treatment: study protocol for a multicentre, randomised superiority trial (SCULPT trial)BMJ Open · 2025