Optimizing flexible and navigable ureteral access sheaths (FANS) manoeuvrability: the impact of sheath size, working channel occupancy and deflection technique - an EAU endourology in vitro analysis.
Steffi Kar Kei Yuen, Vineet Gauhar, Alex Qinyang Liu, Ivan Ching Ho Ko, Yuen Hei Chung, Jia-Lun Kwok, Chi-Ho Leung, David Ka-Wai Leung,
S.H. Ho Urology Centre, Department of Surgery, The Chinese University of Hong Kong, Hong Kong, China. steffiyuen@surgery.cuhk.edu.hk. · European Association of Urology Section of Endourology (ESEUT), Arnhem, The Netherlands.
Key points
From the paper's conclusion- Gaining better understanding of the performance of FANS can ultimately guide clinicians in their selection and optimal utilization of the instrument to enhance procedural efficacy and treatment outcomes.
Abstract
INTRODUCTION: Conventional ureteral access sheaths are placed below the ureteropelvic junction (UPJ), whereas the novel flexible and navigable suction ureteral access sheaths (FANS) are navigated across the UPJ with its distal tip deflected into target calyx under endoscopic guidance to facilitate stone fragments suctioning. We evaluate how FANS deflection angles are affected by sheath sizes, occupancy of working channel (WC) (empty, occupied by Olympus Soltive™ Thulium Laser Fiber 150 μm and 200 μm core diameter) and deflection techniques (ureteroscope deflection versus sheath advancement) across four brands of FANS. MATERIALS & METHODS: In-vitro deflection angles of brand new FANS (sheath sizes 10/12Fr, 11/13Fr and 12/14Fr) ClearPetra (Well Lead Medical Co., Ltd, China) 46 cm, Elephant II (YiGao Medical Technology Co., Ltd, China) 50 cm, Innovex (Innovex Medical Co., Ltd, Shanghai, China) 50 cm, and Reborn (Hunan Reborn Medical Science and Technology Development Co., Ltd, China) 50 cm with brand new single-use flexible ureteroscope Pusen Uscope 7.5Fr PU3033A (Zhuhai Pusen Medical Technology Co., Ltd. Guangzhou, China) were measured in triplicate with varied WC occupancy and forementioned techniques. Maximum deflection angle was expressed as a mean of 3 measurements. One-way ANOVA test was performed for comparisons of the effect of sheath sizes, sheath brands, working channel occupancy, and different deflection techniques. Four-way ANOVA test was performed to evaluate the influence of the aforementioned four factors on the maximal deflection angle, with analysis on the main effects and interaction. For all tests, a two-sided p-value less than 0.05 was considered statistically significant. Statistical tests were performed with SPSS version 26.0 (IBM Corp., Armonk, NY, USA). RESULTS: 10/12Fr and 11/13Fr sheath sizes have significantly better deflection angles than 12/14Fr across all brands with a 7.5Fr flexible ureteroscope. Sheath advancement technique was significantly better with ureteroscope deflection technique. There is no significant difference in deflection angles with occupancy of 150-200 μm fiber. CONCLUSION: Gaining better understanding of the performance of FANS can ultimately guide clinicians in their selection and optimal utilization of the instrument to enhance procedural efficacy and treatment outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Steerable versus Conventional flexible and navigable suction ureteral access sheath (FANS) flexible Ureteroscopy for Lower Pole stones Treatment: study protocol for a multicentre, randomised superiority trial (SCULPT trial)BMJ Open · 2025
- Comparative Study of Flexible Navigable Suction Access Sheaths Versus Conventional Ureteral Access Sheaths in Retrograde Intrarenal Surgery: A Prospective Single-Center Evaluation of Efficiency and Safety.Urologia internationalis · 2026
- A prospective multicenter study of Flexible ureteroscopy using different flexible and navigable suction access sheath (FANS) sizes: peri and 30-day postoperative outcomes from the global and prospective multicenter FLEXible ureteroscopy Outcomes Registry using FANS (FLEXOR-F) by the EAU section of endourology.Minerva urology and nephrology · 2026
- Working Channel Position and Flexible Ureteroscope Performance: An In Vitro Comparative Study.Journal of visualized experiments : JoVE · 2026
- Flexible and navigable suction ureteral access sheath–assisted versus conventional ureteral access sheath–based strategies for retrograde intrarenal surgery of lower pole renal stones: a retrospective cohort studyBMC Urology · 2026
- The global flexible and navigable suction ureteral access sheaths (FANS) survey on utility, practices and future needs in flexible ureteroscopy: a EAU Endourology, PEARLS and IAU collaborationWorld Journal of Urology · 2026