A Comparative Evaluation of YOLO-Segmentation Models for Coronary Artery Segmentation on the ARCADE Dataset.
Ziwei Zhou, Zhangyu Li, Yifang Gao
East University of Heilongjiang. · Nanjing University of Information Science and Technology.
Key points
From the paper's conclusion- This protocol therefore provides a reproducible, image-level comparison of five You Only Look Once (YOLO) segmentation models-YOLOv8-seg, YOLOv9c-seg, YOLO11-seg, YOLO12-seg, and YOLO26-seg-on the public Roboflow v1 ARCADE release of 3,587 expert-annotated frames divided into 3,138 training, 299 validation, and 150 test frames.
Abstract
Coronary X-ray angiography is the clinical reference for visualizing coronary anatomy, but automated instance-level segment labeling remains difficult because of low contrast, overlapping branches, class imbalance across 25 SYNTAX-defined segments, and heterogeneous published protocols. This protocol therefore provides a reproducible, image-level comparison of five You Only Look Once (YOLO) segmentation models-YOLOv8-seg, YOLOv9c-seg, YOLO11-seg, YOLO12-seg, and YOLO26-seg-on the public Roboflow v1 ARCADE release of 3,587 expert-annotated frames divided into 3,138 training, 299 validation, and 150 test frames. Models were initialized from official segmentation checkpoints, trained only on the training split with shared stochastic gradient descent (SGD) settings and validation-based early stopping and checkpoint selection, and evaluated once post hoc on the untouched test split; mask mean average precision (mAP) at intersection over union (IoU) thresholds of 0.50-0.95 (mAP@50-95) was the primary accuracy metric and A100 model-level latency at 32-bit floating-point precision (FP32) was a secondary efficiency descriptor. On validation, the larger YOLOv9c-seg obtained the highest observed mask mAP@50-95 of 0.210; on the test split, compact YOLO11-seg obtained the highest observed mask mAP@50-95 of 0.241, followed by YOLO26-seg (0.239) and YOLOv9c-seg (0.235). Major proximal segments were consistently easier to segment than rare distal variants, while recorded inference times of 0.6 ms versus 3.0 ms per frame describe model-level throughput rather than end-to-end clinical latency. These single-seed, image-level results do not establish patient-level independence, statistical superiority, or clinical utility; they are intended as a methodological benchmark that others can reimplement, with prospective, hardware-specific, and patient-level validation still required before any workflow claim.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Improving Coronary Artery Stenosis Segmentation Performance of YOLO Models Through a Dataset Expansion Strategy Based on Local Focused Augmentation.Journal of imaging informatics in medicine · 2026
- SAK-YOLO: An Improved YOLOv11-Based Method for Coronary Artery Stenosis Segmentation and Grading Judgment.Journal of imaging informatics in medicine · 2026
- PPCAR-Net: Projection-Refined Parametric 3D Coronary Artery Reconstruction from Sparse X-ray Angiographic ViewsarXiv · 2026
- Cross-Architectural Feature Fusion for Coronary Artery Stenosis Detection in X-ray AngiographyarXiv · 2026
- Robust cross center coronary artery segmentation on computed tomography angiography with limited local annotationsEuropean Heart Journal · 2026
- Fully Automated Segmentation of Chronic Total Occlusion Lesions on Coronary CT Angiography Using Deep Learning.Journal of imaging informatics in medicine · 2026