Journal of imaging informatics in medicine

Fully Automated Segmentation of Chronic Total Occlusion Lesions on Coronary CT Angiography Using Deep Learning.

Yang Liu, Haoran Xing, Wancheng Liu, Linjie Liu, Dongfeng Zhang, Rongchong Huang, Jinfan Tian, Lijun Zhang,

School of Engineering Medicine and School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China. · Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Anzhen Road No. 2, Chaoyang District, Beijing, China.

Computational · n=551

Key points

From the paper's conclusion
  • Overall, AAU-Net showed favorable segmentation performance under reference-defined localization, but the fully automated workflow demonstrated lower performance that varied across centers.

Abstract

Reliable quantitative assessment for chronic total occlusion (CTO) lesions depends on accurate segmentation of coronary computed tomography angiography (CCTA) images. However, incomplete contrast opacification and complex lesion morphology make precise delineation particularly challenging. We developed an Atrous Attention U-Net (AAU-Net) for CTO segmentation and integrated it into a fully automated workflow comprising heart localization, CTO localization, and lesion segmentation. This retrospective study included 565 CTO lesions from 551 patients who underwent prospectively ECG-gated CCTA at three centers. Standalone segmentation used reference-mask-derived lesion-containing slices and regions of interest, whereas the automated workflow used predicted localization without reference-mask information or manual correction. Under reference-defined localization, AAU-Net achieved a Dice score of 0.8421 and intersection over union of 0.7312 in the internal test set, although performance varied by anatomical location and center. Performance decreased in the fully automated workflow, with Dice scores of 0.6922 in the internal test set, 0.5822 in external test set 1, and 0.6480 in external test set 2, potentially reflecting localization errors and differences between the separately trained segmentation models. In an exploratory locked-model radiomics analysis, features derived from automated segmentations showed numerically lower predictive performance than those derived from manual segmentations. Overall, AAU-Net showed favorable segmentation performance under reference-defined localization, but the fully automated workflow demonstrated lower performance that varied across centers. The radiomics findings demonstrate technical feasibility rather than established clinical utility. Further optimization and larger prospective multicenter validation are required before clinical deployment.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Fully Automated Segmentation of Chronic Total Occlusion Lesions on Coronary CT Angiography Using Deep Learning — Science Skim