Impact of Ureteral Access Sheath Size During Flexible Ureteroscopy Using a 6 o'clock Working Channel: A Prospective Multicenter Pilot Study.
Sang Hoon Song, Joo Yong Lee, Sung Yong Cho
Department of Urology, Asan Medical Center, University of Ulsan, College of Medicine. · Department of Urology, Severance Hospital, Urological Science Institute, Yonsei University College of Medicine.
Key points
From the paper's conclusion- The impact of ureteral access sheath (UAS) size on surgical outcomes in flexible ureteroscopy (f-URS) remains controversial, particularly with modern suction-assisted techniques and evolving definitions of stone-free status.
Abstract
The impact of ureteral access sheath (UAS) size on surgical outcomes in flexible ureteroscopy (f-URS) remains controversial, particularly with modern suction-assisted techniques and evolving definitions of stone-free status. The objective of this study was to evaluate the effect of UAS size on stone-free rate (SFR), operative efficiency, and fragment clearance dynamics during f-URS for lower-pole stones using a 6 o'clock working-channel ureteroscope. This prospective multicenter pilot study included 49 patients undergoing f-URS across three tertiary referral centers. The primary outcome was strict SFR (0 mm), and secondary outcomes included clinical SFR (<2 mm), operative time, laser lithotripsy time, and fragment clearance patterns. Subgroup analysis focused on lower-pole stones. No statistically significant difference in strict SFR was observed between the 11/13 Fr and 12/14 Fr UAS groups. Clinical SFR also did not differ significantly between groups, although it was higher than strict SFR, particularly for lower-pole stones. Mean operative time was comparable between groups. Laser lithotripsy time was numerically longer in the 12/14 Fr group, but the difference was not statistically significant. Given the limited sample size, the findings should be considered exploratory and require confirmation in larger prospective studies. Trends in operative parameters and fragment clearance were observed and should be interpreted cautiously. Operative performance metrics and fragment clearance patterns may complement traditional binary stone-free outcomes when evaluating endourological innovations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Impact of Ureteral Access Sheath Use on Renal Stone Clearance During Flexible Ureterorenoscopy: A Retrospective Cohort StudyHealth Science Reports · 2026
- Comparative study of ureteral access sheath versus suction access sheath in retrograde intrarenal surgeryBMC Urology · 2025
- Network meta-analysis of clinical efficacy and safety of flexible ureteroscopic holmium laser lithotripsy combined with tip-flexible suction ureteral access sheath for kidney stones.American journal of translational research · 2026
- Comparative Study of Flexible Navigable Suction Access Sheaths Versus Conventional Ureteral Access Sheaths in Retrograde Intrarenal Surgery: A Prospective Single-Center Evaluation of Efficiency and Safety.Urologia internationalis · 2026
- Selective Omission of Ureteral Access Sheath in Retrograde Intrarenal Surgery: Surgical and Safety Outcomes from a Single-Center Retrospective Cohort StudyJournal of Clinical Medicine · 2026
- A "stepped" flexible vacuum-assisted ureteral access sheath improves stone clearance efficiency: experimental results from an ex vivo porcine model.Frontiers in surgery · 2026