Biomechanical analysis of diamond-like carbon coated growth-guidance spinal system under cyclic axial compression.
Małgorzata Żak, Sylwia Szotek, Klaudia Szkoda-Poliszuk, Krzysztof Kołtowski, Piotr Menartowicz, Celina Pezowicz
Department of Mechanics, Materials and Biomedical Engineering, Faculty of Mechanical Engineering, Wrocław University of Science and Technology, Wrocław, Poland. · Department of Pediatric Surgery and Urology, Wroclaw Medical University, Wrocław, Poland.
Key points
From the paper's conclusion- DLC coating did not increase overall construct stiffness during cyclic axial compression, but it modified local mechanical behaviour and was associated with preservation of segmental mobility at selected levels. Further studies should determine whether these effects are maintained under multi-axis loading and in long-term tribological conditions.
Abstract
PURPOSE: Growth-guidance spinal systems are used in children with progressive spinal deformity to reduce repeated surgical lengthening while allowing continued spinal growth. Their long-term biomechanical behaviour under cyclic loading remains insufficiently characterised. This study assessed whether diamond-like carbon (DLC) coating of rods and sliding screws affects axial stiffness and local kinematics in a growth-guidance spinal system. METHODS: Twelve porcine Th11-L7 spine specimens were assigned to three groups: non-instrumented control, non-coated titanium alloy instrumentation, and instrumentation with DLC-coated components. Specimens underwent 100,000 cycles of axial compression. Axial stiffness was evaluated after 100 and 100,000 cycles. Vertebral range of motion from Th12 to L6 was measured using rigid body markers, and local rod-screw interface displacements were assessed using three-dimensional digital image correlation. RESULTS: Stiffness increased similarly in all groups up to approximately 80,000 cycles. After 100,000 cycles, construct stiffness was approximately 6% lower in DLC coated instrumentation than in non-coated titanium alloy instrumentation. In the coated construct, segmental mobility at Th12-L1 and L5-L6 remained closer to the non-instrumented condition, whereas non-coated titanium alloy instrumentation showed reduced motion at these levels. Digital image correlation demonstrated time-dependent differences in local rod-screw interface kinematics between coated and non-coated constructs. CONCLUSION: DLC coating did not increase overall construct stiffness during cyclic axial compression, but it modified local mechanical behaviour and was associated with preservation of segmental mobility at selected levels. Further studies should determine whether these effects are maintained under multi-axis loading and in long-term tribological conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biomechanical Comparison of Composite versus Screw-Rod Fixation for Posterior C5-C6 Fusion.Global spine journal · 2026
- Greater deformation and lower stiffness, but similar ultimate failure strength with fixed-loop cortical suspensory device compared to metal interference screw for femoral fixation of bone-patellar tendon-bone grafts in anterior cruciate ligament reconstruction.Journal of experimental orthopaedics · 2026
- Bioplating demonstrates increasing micromovement during cyclic loading after anterior closed wedge high tibial osteotomy despite no significant difference in failure load compared to angle-stable plate fixation.Journal of experimental orthopaedics · 2026
- A Novel Titanium End-Disc-Assisted Allograft Preparation System for Anterior Cervical Corpectomy and Fusion: Development and Preliminary Biomechanical Evaluation.Bioengineering (Basel, Switzerland) · 2026
- Preclinical Cyclic Testing of Adjunctive Fixation of the Humeral Epicondyle in a Lateral Condylar Fracture Model: Ex Vivo Comparison of a Locking Plate versus a Light-curable Composite.Veterinary and comparative orthopaedics and traumatology : V.C.O.T · 2026
- From nature to engineering: A comprehensive mechanical response analysis of novel bio-inspired CFRP adhesive jointsThin-Walled Structures · 2026