Japanese Journal of Applied Physics

Physical origin and suppression of geometric components in charge pumping of 4H-SiC n-channel MOSFETs

Shuto Oi, Mitsuru SOMETANI, Hirohisa Hirai, Mitsuo Okamoto, Tetsuo HATAKEYAMA

Key points

From the paper's conclusion
  • In charge-pumping (CP) measurements of 4H-SiC n-channel MOSFETs, a geometric component (GC) unrelated to interface traps can cause overestimation of interface-trap density.

Abstract

In charge-pumping (CP) measurements of 4H-SiC n-channel MOSFETs, a geometric component (GC) unrelated to interface traps can cause overestimation of interface-trap density. We investigated the channel-length and gate-pulse fall-time dependences of CP current using experiments and transient TCAD simulations. The CP current density increased with channel length at short fall times, whereas this increase was suppressed at longer fall times. Spatial distributions of electron concentration, electron transport, and Shockley–Read–Hall (SRH) recombination revealed residual electrons near the channel center and recombination in the bulk region during the gate-voltage fall. These observations are consistent with the proposed mechanism in which recombination involving residual electrons contributes to GC generation. By comparing the characteristic electron diffusion length with the distance to the source/drain regions, we derived an approximate critical channel length, L crit =2√( D n ∗ t f ), which explains the observed GC generation and suppression trends.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers