Development of a Flow Cytometric Immunoassay Using Recombinant Vascular Endothelial Growth Factor (VEGF)-Functionalized Poly(ε-Caprolactone) Microbeads for Bevacizumab Quantification.
Negar Namaei-Ghasemnia, Mohammad Rabiee, Fatemeh Davami, Yeganeh Talebkhan-Garoosi, Mohamad Ghorbani
Biomaterial Group, Department of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran. · Biotechnology Research Center, Pasteur Institute of Iran, Tehran, Iran.
Key points
From the paper's conclusion- Considering the ease of fabrication and functionalization of PCL MBs under the obtained optimal conditions, along with their capability for analyte detection, these cost-effective analytical platforms may serve as promising candidates for BVZ quantification.
Abstract
PURPOSE: With the growing research interest in therapeutic monoclonal antibodies (mAbs) and their broad range of applications, the development of reliable analytical approaches for their quantification has become increasingly important. Since, microbead (MB)-based flow cytometric immunoassays have emerged as highly sensitive analytical methods, the aim of this study was to develop and evaluate a flow cytometry-based method using poly(ε-caprolactone) (PCL) MBs to quantify bevacizumab (BVZ) concentration. METHODS: PCL MBs were synthesized through the emulsion/solvent evaporation method and modified by reaction with 1,2-ethylenediamine (EDA) to enable covalent binding of biomolecules. Based on the optimal biomolecule immobilization conditions determined using a model protein, purified recombinant vascular endothelial growth factor (VEGF) protein was immobilized on the surface of amine-functionalized MBs (A-MBs(45)) to capture BVZ, which was then detected using fluorescein isothiocyanate (FITC)-conjugated anti-human IgG antibody in flow cytometry. RESULTS: The synthesized PCL MBs, with an average diameter of 6.62±0.17 µm, were within the suitable particle size range for immunoassay applications. The optimal aminolysis time was found to be 45 min at 37 °C, and the maximum protein coupling was achieved 5 h post-incubation at pH 8.0. The developed MB-based flow cytometric immunoassay demonstrated the potential to quantify BVZ with a limit of detection (LOD) and limit of quantification (LOQ) of about 6.71 and 22.73 ng mL-1, respectively. CONCLUSION: Considering the ease of fabrication and functionalization of PCL MBs under the obtained optimal conditions, along with their capability for analyte detection, these cost-effective analytical platforms may serve as promising candidates for BVZ quantification.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Polycaprolactone Hollow Fiber Membranes for Sustained Bevacizumab ReleaseChem & Bio Engineering · 2026
- Mucoadhesive Cationic Liposome Nanoparticles Coated with Methacrylated Hyaluronic Acid for Ocular Drug DeliveryACS Applied Nano Materials · 2025
- Polydopamine-modified BODIPY-encoded polystyrene microspheres for highly sensitive multiplexed miRNA detection.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026
- Geometry driven machine learning guided fabrication of sub-5 µm PLGA microparticles for balloon catheter drug delivery.Analytical methods : advancing methods and applications · 2026
- FP003B suppresses microcarrier aggregation and enhances cell yield in microcarrier-based mesenchymal stromal cell culture.Frontiers in bioengineering and biotechnology · 2026
- Data-driven and mechanistic modelling of PLGA nanoparticle formation in hydrodynamic flow focusing microfluidics.Lab on a chip · 2026