Analytical methods : advancing methods and applications

Geometry driven machine learning guided fabrication of sub-5 µm PLGA microparticles for balloon catheter drug delivery.

Mohamed S Ibrahim, Mahmoud Ashraf, Hassan Beheshti Seresht, Mia C Chupein, Chang Hun Kum, Jae Hwa Cho, Gyuhyun Jin, Sang Hyun An,

Department of Industrial Engineering, University of Pittsburgh, Pittsburgh, PA, USA. · Department of Bioengineering, University of Pittsburgh, PA, USA. say8@pitt.edu.

Computational · n=2,000

Key points

From the paper's conclusion
  • This study demonstrates stable generation of sub-5 µm PLGA microparticles by integrating a shear-modulating obstruction into a cross-junction microfluidic device to enhance droplet breakup under laminar flow.

Abstract

Poly (lactic-co-glycolic acid) (PLGA) microparticles are widely used as biodegradable drug-delivery carriers, where particle size critically governs drug release kinetics, degradation behavior, and overall therapeutic performance. Producing sub-5 µm PLGA microparticles in PDMS microfluidic devices remains challenging due to limited shear control, PDMS swelling in organic solvents, and instability at high flow-rate ratios. This study demonstrates stable generation of sub-5 µm PLGA microparticles by integrating a shear-modulating obstruction into a cross-junction microfluidic device to enhance droplet breakup under laminar flow. Computational Fluid Dynamics (CFD) simulations and initial experiments showed that positioning a 150 µm-wide obstruction 5 µm downstream shifted droplet formation into a stable dripping regime, reducing droplet size from 84 ± 5 µm (10 : 1) and 32 ± 3 µm (20 : 1) in the unobstructed device to 8 ± 0.7 µm with controlled pinch-off, followed by a machine-learning-guided optimization model to identify parameter combinations that yielded 3.6-4.5 µm microparticles under optimized conditions. A Polynomial Regression surrogate model in a machine learning-assisted optimization accurately captured nonlinear interactions between flow-rate ratio, obstruction width, and obstruction distance. Coupling the model with randomized grid search (n = 2000) yielded design combinations that experimentally reproduced particle sizes within <3% error for four of five candidate models. Finally, a thermoresponsive biodegradable polymer adhesive enabled temperature-activated attachment of the unloaded PLGA microparticles to a coronary balloon catheter and partial particle transfer during balloon inflation in a simplified silicone arterial model, providing an enabling platform for future catheter-based drug-delivery studies.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Geometry driven machine learning guided fabrication of sub-5 µm PLGA microparticles for balloon catheter drug delivery — Science Skim